Vertical Stage Pumps

Vertical Stage Pumps

The vertical stage pumps we have manufactured are 1450 RPM with 0.75 – 45 KW and 2900 RPM with 0.75 -110 KW water pumps that make it easier to use in places with horizontal space problems.

They are water pumps which are suitable for use in agricultural irrigation, industrial sector, purification systems, food industry, chemical industry, in addition to areas where horizontal products are used as a field of use, and can also be manufactured with bronze impellers, stainless impellers, Noryl impellers and steel cast impellers. Turkey manufacturer of staged water pump.

SHM6 - SHT6

Definition

These pumps with a stainless steel body, vertical shaft and multi-stage are high altitude, silent operation and non self priming pumps. It is designed for use in pressurizing low viscosity liquids. The pump saves space due to its vertical structure.
These pumps are manufactured at frequencies of 50 Hz and 60 Hz.

Usage Areas

These pumps are used in residential areas, industrial facilities, irrigation applications requiring pressure, for Booster purposes in villas, summer houses and high rise buildings, in industries, hospitals, hotels, public housing, holiday villages, shopping malls, social facilities, fire systems, garden irrigation, heating and cooling systems.

Pump Material Characteristics

Pump BodyAISI 304 INOX
ImpellerNORYL
ShaftAISI 420
Flow Rate (max)6 m³/hour
Total Head (max)92 m
Liquid Temperature0-45°C 
Protection ClassIP 54
InsulationCI.F
Mechanical SealCERAMIC/CARBON
Pump Durability Pressure (Pmax)12 bar

Technical Specifications

MOTOR
PUMP
TypeKWHPVHzArpm

capacitor

uf     Vc

Hm

input

outputKG m³/h123 45
SHM6-100/60.751220505290020450551″17.5

mss

5246382510
SHT6-100/60.751380502.42900551″185246382510
SHM6-150/81.11.5220505.529002545072 1″196560483210
SHT6-150/81.11.5380502.42900 721¼ 1″18.56860483210
SHT6-180/101.351.8380503.2290092 1¼  1″208372573710
Dimensions
TypeWLHH1H2E

F

DNMDNA
SHM6-100/615721547133228137166G1¼G1″
SHM6-150/815721547133279137166G1¼G1″
SHT6-180/1015721555033330137166G1¼G1″

 

SHM8 - SHT8

Definition

These pumps with a stainless steel body, vertical shaft and multi-stage are high altitude, silent operation and non self priming pumps. It is designed for use in pressurizing low viscosity liquids. The pump saves space due to its vertical structure.
These pumps are manufactured at frequencies of 50 Hz and 60 Hz.

Usage Areas

These pumps are used in residential areas, industrial facilities, irrigation applications requiring pressure, for Booster purposes in villas, summer houses and high rise buildings, in industries, hospitals, hotels, public housing, holiday villages, shopping malls, social facilities, fire systems, garden irrigation, heating and cooling systems.

Pump Material Characteristics

Pump BodyAISI 304 INOX
ImpellerNORYL
ShaftAISI 420
Flow Rate (max)8 m³/hour
Total Head (max)135 m
Liquid Temperature0-45°C 
Protection ClassIP 54
InsulationCI.F
Mechanical SealCERAMIC/CARBON
Pump Durability Pressure (Pmax)16 bar

Technical Specifications

MOTOR
PUMP
TypeKWHPVHzArpm

capacitor

uf     Vc

Hm

input

outputKG m³/h123 57
SHM8-220/61.62.22205010290045450831″26.5

mss

8077705025
SHT8-220/61.62.2380505.22900831″258077705025
SHM8-300/82.232205013.22900504501101″29105100907030
SHT8-300/82.23380505.42900 1101¼ 1″27105100907030
SHT8-400/1034380506.429001351¼  1″301271201108038
SHT8-450/123.454.5380507.22900  1631¼  1″ 311501401269244
Dimensions
TypeWLHH1H2E

F

DNMDNA
SHM8-220/617926352835211156185G1¼G1″
SHM8-300/817926360035257156185G1¼G1″
SHT8-400/1017926364535304156185G1¼G1″
SHT8-450/1217926368635351156185G1¼G1″

 

SHM12 - SHT12

Definition

These pumps with a stainless steel body, vertical shaft and multi-stage are high altitude, silent operation and non self priming pumps. It is designed for use in pressurizing low viscosity liquids. The pump saves space due to its vertical structure.
These pumps are manufactured at frequencies of 50 Hz and 60 Hz.

Usage Areas

These pumps are used in residential areas, industrial facilities, irrigation applications requiring pressure, for Booster purposes in villas, summer houses and high rise buildings, in industries, hospitals, hotels, public housing, holiday villages, shopping malls, social facilities, fire systems, garden irrigation, heating and cooling systems.

Pump Material Characteristics

Pump BodyAISI 304 INOX
ImpellerNORYL
ShaftAISI 420
Flow Rate (max)12 m³/hour
Total Head (max)96 m
Liquid Temperature0-45°C 
Protection ClassIP 54
InsulationCI.F
Mechanical SealCERAMIC/CARBON
Pump Durability Pressure (Pmax)14 bar

Technical Specifications

MOTOR
PUMP
TypeKWHPVHzArpm

Capacitor

uf     Vc

Hm

input

outputKG m³/h246810
SHM12-220/41.62.222050112900454506026

mss

5753504332
SHT12-220/41.62.2380505.529006024.55753504332
SHM12-300/62.232205014.22900504508228.57772635237
SHT12-300/62.23380505.72900 821¼ 277772635237
SHT12-400/734380506.52900961¼  299187766547
SHT12-450/83.454.5380507.22900–  –1211¼   30.5113105927860
Dimensions
TypeWLHH1H2E

F

DNMDNA
SHM12-220/417927050135183156172G1¼G1¼
SHM12-300/617927055135240156172G1¼G1¼
SHT12-400/717927058535268156172G1¼G1¼
SHT12-450/817927062835296156172G1¼G1¼

 

SHT16

Definition

These pumps with a stainless steel body, vertical shaft and multi-stage are high altitude, silent operation and non self priming pumps. It is designed for use in pressurizing low viscosity liquids. The pump saves space due to its vertical structure.
These pumps are manufactured at frequencies of 50 Hz and 60 Hz.

Usage Areas

These pumps are used in residential areas, industrial facilities, irrigation applications requiring pressure, for Booster purposes in villas, summer houses and high rise buildings, in industries, hospitals, hotels, public housing, holiday villages, shopping malls, social facilities, fire systems, garden irrigation, heating and cooling systems.

Pump Material Characteristics

Pump BodyAISI 304 INOX
ImpellerNORYL
ShaftAISI 420
Flow Rate (max)16 m³/hour
Total Head (max)142 m
Liquid Temperature0-45°C 
Protection ClassIP 54
InsulationCI.F
Mechanical SealCERAMIC/CARBON
Pump Durability Pressure (Pmax)16 bar

Technical Specifications

MOTOR
PUMP
TypeKWHPVHzArpm

Hm

input

outputKG m³/h26101216
SHT16-550/445.538050829007441

mss

7065524530
SHT16-550/545.5380509.7290090418878675837
SHT16-750/65.57.53805011.2290011046.510594786844
SHT16-750/75.57.53805011.4290012546.5120109918050
SHT16-850/86.38.53805012.82900142 511351211049059
Dimensions
TypeWLHH1H2E

F

DNMDNA
SHT16-550/420030858040206174219G1½G1¼
SHT16-550/520030864040239174219G1½G1¼
SHT16-750/620030866040272174219G1½G1¼
SHT16-750/720030869040305174219G1½G1¼
SHT16-850/820030872040338174219G1½G1¼

 

SHT24

Definition

These pumps with a stainless steel body, vertical shaft and multi-stage are high altitude, silent operation and non self priming pumps. It is designed for use in pressurizing low viscosity liquids. The pump saves space due to its vertical structure.
These pumps are manufactured at frequencies of 50 Hz and 60 Hz.

Usage Areas

These pumps are used in residential areas, industrial facilities, irrigation applications requiring pressure, for Booster purposes in villas, summer houses and high rise buildings, in industries, hospitals, hotels, public housing, holiday villages, shopping malls, social facilities, fire systems, garden irrigation, heating and cooling systems.

Pump Material Characteristics

Pump BodyAISI 304 INOX
ImpellerNORYL
ShaftAISI 420
Flow Rate (max)30 m³/hour
Total Head (max)120 m
Liquid Temperature0-45°C 
Protection ClassIP 54
InsulationCI.F
Mechanical SealCERAMIC/CARBON
Pump Durability Pressure (Pmax)16 bar

Technical Specifications

MOTOR
PUMP
TypeKWHPVHzArpm

Hm

input

outputKG m³/h812162024
SHT24-550/445.53805082900602″62.5

mss

5145373020
SHT24-750/55.57.538050112900752″68.56557503925
SHT24-750/65.57.538050112900872″69.57768574533
SHT24-1000/77.510380501529001002″87.58778675540
SHT24-1000/87.510380501529001202″ 8910595806751
Dimensions
TypeWLHH1H2E

F

DNMDNA
SHT24-550/422531890644279206250G2″G1½
SHT24-750/522531897044327206250G2″G1½
SHT24-750/6225318101044375206250G2″G1½
SHT24-1000/7225318112044423206250G2″G1½
SHT24-1000/8225318117044471206250G2″G1½

 

SHT34

Definition

These pumps with a stainless steel body, vertical shaft and multi-stage are high altitude, silent operation and non self priming pumps. It is designed for use in pressurizing low viscosity liquids. The pump saves space due to its vertical structure.
These pumps are manufactured at frequencies of 50 Hz and 60 Hz.

Usage Areas

These pumps are used in residential areas, industrial facilities, irrigation applications requiring pressure, for Booster purposes in villas, summer houses and high rise buildings, in industries, hospitals, hotels, public housing, holiday villages, shopping malls, social facilities, fire systems, garden irrigation, heating and cooling systems.

Pump Material Characteristics

Pump BodyAISI 304 INOX
ImpellerNORYL
ShaftAISI 420
Flow Rate (max)36 m³/hour
Total Head (max)120 m
Liquid Temperature0-45°C 
Protection ClassIP 54
InsulationCI.F
Mechanical SealCERAMIC/CARBON
Pump Durability Pressure (Pmax)16 bar

Technical Specifications

MOTOR
PUMP
TypeKWHPVHzArpm

Hm

input

outputKG m³/h1218243036
SHT34-750/45.57.538050112900702″63

mss

6458503920
SHT34-1000/57.51038050152900892″848075645125
SHT34-1500/61115380502029001002″969388786233
SHT34-1500/71115380502229001202″97.5112106978145
Dimensions
TypeWLHH1H2E

F

DNMDNA
SHT34-550/422531890644279206250G2″G1½
SHT34-1000/5225318103044327206250G2″G1½
SHT34-1500/6225318110044375206250G2″G1½
SHT34-1500/7225318115044432206250G2″G1½

 

SHT32

Definition

These pumps with a cast iron body, cast iron impeller, vertical shaft and multi-stage are high altitude, silent operation and non self priming pumps. It is designed for use in pressurizing low viscosity liquids. The pump saves space due to its vertical structure.
These pumps are manufactured at frequencies of 50 Hz and 60 Hz.

Usage Areas

These pumps are used in residential areas, industrial facilities, irrigation applications requiring pressure, for Booster purposes in villas, summer houses and high rise buildings, in industries, hospitals, hotels, public housing, holiday villages, shopping malls, social facilities, fire systems, garden irrigation, heating and cooling systems.

Pump Material Characteristics

Pump BodyGG25 CAST IRON
ImpellerGG25 CAST IRON
ShaftAISI 420
Flow Rate (max)16 m³/hour
Total Head (max)150 m
Liquid Temperature0-45°C 
Protection ClassIP 54
InsulationCI.F
Mechanical SealCERAMIC/CARBON
Pump Durability Pressure (Pmax)16 bar

Technical Specifications

MOTOR
PUMP
TypeKWVHzArpm

Hm

input

outputKG m³/h68101216
SHT32/24380508290050DN40DN3283

mss

4847464435
SHT32/34380509290075DN40DN32907372706552
SHT32/45.538050112900100DN40DN321009895918668
SHT32/57.538050152900125DN40DN3212612312011511085
SHT32/61138050222900150DN40DN32144 147145139130106
Dimensions
TypeWLHH1H2E

F

DNMDNA
SHT32/2270240820100131241250DN40DN32
SHT32/3270280870100179241250DN40DN32
SHT32/4270303912100227241250DN40DN32
SHT32/5270380990100275241250DN40DN32
SHT32/62704281040100323241250DN40DN32

 

SHT40

Definition

These pumps with a cast iron body, cast iron impeller, vertical shaft and multi-stage are high altitude, silent operation and non self priming pumps. It is designed for use in pressurizing low viscosity liquids. The pump saves space due to its vertical structure.
These pumps are manufactured at frequencies of 50 Hz and 60 Hz.

Usage Areas

These pumps are used in residential areas, industrial facilities, irrigation applications requiring pressure, for Booster purposes in villas, summer houses and high rise buildings, in industries, hospitals, hotels, public housing, holiday villages, shopping malls, social facilities, fire systems, garden irrigation, heating and cooling systems.

Pump Material Characteristics

Pump BodyGG25 CAST IRON
ImpellerGG25 CAST IRON
ShaftAISI 420
Flow Rate (max)32 m³/hour
Total Head (max)150 m
Liquid Temperature0-45°C 
Protection ClassIP 54
InsulationCI.F
Mechanical SealCERAMIC/CARBON
Pump Durability Pressure (Pmax)16 bar

Technical Specifications

MOTOR
PUMP
TypeKWVHzArpm

Hm

input

outputKG m³/h1015202530
SHT40/27.53805015290060DN50DN40114

mss

5552504842
SHT40/3113805022290090DN50DN401368582807872
SHT40/41538050302900120DN50DN40199115112110108102
SHT40/518.538050372900150DN50DN40226145142140138132
Dimensions
TypeWLHH1H2E

F

DNMDNA
SHT40/2272350910105145241350DN50DN40
SHT40/3272350965105200241350DN50DN40
SHT40/42723501150105270241350DN50DN40
SHT40/52723501215105310241350DN50DN40

 

SHT50

Definition

These pumps with a cast iron body, cast iron impeller, vertical shaft and multi-stage are high altitude, silent operation and non self priming pumps. It is designed for use in pressurizing low viscosity liquids. The pump saves space due to its vertical structure.
These pumps are manufactured at frequencies of 50 Hz and 60 Hz.

Usage Areas

These pumps are used in residential areas, industrial facilities, irrigation applications requiring pressure, for Booster purposes in villas, summer houses and high rise buildings, in industries, hospitals, hotels, public housing, holiday villages, shopping malls, social facilities, fire systems, garden irrigation, heating and cooling systems.

Pump Material Characteristics

Pump BodyGG25 CAST IRON
ImpellerGG25 CAST IRON
ShaftAISI 420
Flow Rate (max)60 m³/hour
Total Head (max)168 m
Liquid Temperature0-45°C 
Protection ClassIP 54
InsulationCI.F
Mechanical SealCERAMIC/CARBON
Pump Durability Pressure (Pmax)16 bar

Technical Specifications

MOTOR
PUMP
TypeKWVHzArpm

Hm

input

outputKG m³/h35404550
SHT50/2113805022290062DN65DN50165

mss

61605852
SHT50/2153805030290081DN65DN5022078757268
SHT50/318.538050372900110DN65DN5025495928881
SHT50/32238050402900125DN65DN50289112110105100
SHT50/42238050442900139DN65DN50307122120112108
SHT50/43038050572900168DN65DN50316152150142137
Dimensions
TYPEWLHH1H2E

F

DNMDNA
SHT50/2 11 KW3303501050120169300350DN65DN50
SHT50/2 15 KW3303501070120169300350DN65DN50
SHT50/3 18.5 KW3303501135120236300350DN65DN50
SHT50/3 22 KW3303501155120236300350DN65DN50
SHT50/4 22 KW3303501218120303300350DN65DN50
SHT50/4 30 KW3303501238120303300350DN65DN50

 

SHT65

Definition

These pumps with a cast iron body, cast iron impeller, vertical shaft and multi-stage are high altitude, silent operation and non self priming pumps. It is designed for use in pressurizing low viscosity liquids. The pump saves space due to its vertical structure.
These pumps are manufactured at frequencies of 50 Hz and 60 Hz.

Usage Areas

These pumps are used in residential areas, industrial facilities, irrigation applications requiring pressure, for Booster purposes in villas, summer houses and high rise buildings, in industries, hospitals, hotels, public housing, holiday villages, shopping malls, social facilities, fire systems, garden irrigation, heating and cooling systems.

Pump Material Characteristics

Pump BodyGG25 CAST IRON
ImpellerGG25 CAST IRON
ShaftAISI 420
Flow Rate (max)110 m³/hour
Total Head (max)160 m
Liquid Temperature0-45°C 
Protection ClassIP 54
InsulationCI.F
Mechanical SealCERAMIC/CARBON
Pump Durability Pressure (Pmax)20 bar

Technical Specifications

MOTOR
PUMP
TypeKWVHzArpm

Hm

input

outputKG m³/h60708090
SHT65/2303805060290080DN80DN65297.5

mss

70655750
SHT65/23738050722900100DN80DN65327.590857870
SHT65/34538050882900140DN80DN65559127124120116
SHT65/355380501052900160DN80DN65584148145140135
Dimensions
TypeWLHH1H2E

F

DNMDNA
SHT65/2 30 KW3304201211130200300441DN80DN65
SHT65/2 37 KW3304201231130200300441DN80DN65
SHT65/3 45 KW3304201260130275300441DN80DN65
SHT65/3 55 KW3304201290130275300441DN80DN65

 

Vertical Shaft Multistage Boosters

 Vertical Shaft Multistage Pumps produced by turkish vertical multistage booster manufacturers  They are products that make it easier to use in places where there is a horizontal space problem, they are used for booster purposes, The pumps are designed with more than one impeller and stage on a vertical shaft. Although the material of the pump booster impeller is usually noryl, they can also be manufactured as stainless and cast. Such pumps can also be used as fire pumps in small businesses.

The asynchronous motor driving the pump is designed to be on the top of the pump, the pump is usually connected to the system with an easy mounting apparatus called a glen (flange) and can be easily disassembled in case of maintenance.

Booster systems produced by turkish vertical pump producers  are suitable for use in industries, hospitals, residential units, hotels, mass housing, gas stations, holiday villages, shopping malls, social facilities, fire systems for booster purposes and pressurized water needs.

What does a Booster do? They are electrically operated water pumps produced for the purpose of increasing the water pressure system. The working principle of the booster is, with the help of high pressure, they deliver the water they absorb from a certain water reservoir to distant points.

Due to the expansion tanks connected to the boosters, they already hold pressurized water. Pressurized Water Boosters are used in buildings, apartments, detached villas, estates and high-rise buildings to meet the need for mains water or pressurized water from tanks in cases where the mains water pressure is not sufficient. In short, we can say that it is a water pressurization system used wherever the water pressure is insufficient.

These systems produced by turkish vertical multistage pump manufacturers , most of which work with electricity, increase the pressure of the water flowing from our taps. The difference between the booster and the pump is a detail that is often wondered. Let’s briefly explain this as follows. The booster is a whole system consisting of both the pump and the control equipment that controls the pump’s input and output. The Booster Pump has a system consisting of protection equipment in order to ensure its long-lasting operation, so that it does not focus on a single purpose, the system in general provides control and protection.

Vertical Multistage Booster produced by turkish vertical multistage booster suppliers  is the name given to the pumps that are automatically activated when the water supply is insufficient. It pressurizes the water in the water tank with the pump wheels and pumps it to the far point, in short, this is the working principle.

The selection of the booster pump should be completely tailored to the needs; It should be able to give the pressure to the water to go to the desired place. The booster is not only a system consisting of a water tank and a pump, but also has auxiliary elements mounted. We can count these auxiliary elements as follows; Expansion Tank, Manometer, Check Valve, Ball Valve, Pressure Switch, Control Panel and Water Level Floater.

Regarding the installation of vertical multistage pumps There are some points when calculating the Gradual Booster; the number of flats and the height of the building, the location of the warehouse, the horizontal and vertical pipes in the building installation, the friction coefficient of the water in the water installation, the water supply for how many flats, the distance between the flats to be installed and the flats to be fed, etc. These details are important for choosing the right booster and provide long-term usefulness.

Turkey vertical multistage pump manufacturer / Multistage pump companies /  turkey multistage water pump manufacturer /

Read more