Definition
These boosters are systems that enable water to reach comfortably in cases where the city mains water is insufficient, in high rise buildings, in residential units with tanks for water interruption and they operate completely automatically according to their intended use.
These pumps are manufactured at frequencies of 50 Hz and 60 Hz.
Usage Areas
These pumps are used in residential areas, apartments, villas, schools, hospitals, factories and public housing, hotels and garden irrigation.
Techical Specifications
| PACKAGE BOOSTERS WITH JET PUMP | ||||||||||||
| TYPE | KW | HP | V Mono | V Tri | WORKING PRESSURE | m³/h Max | TANK VOLUME | W mm | L mm | H mm | NUMBER OF FLATS | NUMBER OF FLOORS |
| SMJH 85 (FLOATER) | 0,65 | 0,85 | 220 | 380 | 2 – 4 | 3,5 | 24 | 350 | 440 | 590 | 4 | 4 |
| SMJKH 100 (FLOATER) | 0,75 | 1 | 220 | – | 2 – 4,5 | 3,5 | 24 | 350 | 440 | 590 | 5 | 5 |
| SMJH 150 (FLOATER) | 1,1 | 1,5 | 220 | 380 | 3 – 5 | 4,5 | 50 | 350 | 630 | 720 | 10 | 5 |
| SMJH 220 (FLOATER) | 1,6 | 2,2 | 220 | 380 | 4 – 6 | 6 | 100 | 475 | 845 | 810 | 16 | 8 |
| PACKAGE BOOSTERS WITH STAINLESS CENTRIFUGAL PUMP | ||||||||||||
| TYPE | KW | HP | V Mono | V Tri | WORKING PRESSURE | m³/h Max | TANK VOLUME | W mm | L mm | H mm | NUMBER OF FLATS | NUMBER OF FLOORS |
| SMINOX H 150/4 | 1,1 | 1,5 | 220 | 380 | 3 – 5 | 5,8 | 50 | 350 | 650 | 720 | 12 | 5 |
| SMINOX H 150/4 T | 1,1 | 1,5 | 220 | 380 | 3 – 5 | 5,8 | 50 | 350 | 650 | 720 | 12 | 5 |
| PACKAGE BOOSTERS WITH HORIZONTAL MULTISTAGE PUMP | ||||||||||||
| TYPE | KW | HP | V Mono | V Tri | WORKING PRESSURE | m³/h Max | TANK VOLUME | W mm | L mm | H mm | NUMBER OF FLATS | NUMBER OF FLOORS |
| SYMH6-100/6 SYMTH6-100/6 (FLOATER+CONTROL PANEL) | 0.75 | 1 | 220 | 380 | 3-5 | 6 | 100 | 505 | 795 | 840 | 12-16 | 6-3 |
| SYMH6-150/8 SYMTH6-150/8 (FLOATER+CONTROL PANEL) | 1.1 | 1.5 | 220 | 380 | 4-6 | 6 | 100 | 505 | 880 | 840 | 12-18 | 9-4 |
| SYMH8-220/6 SYMTH8-220/6 (FLOATER+CONTROL PANEL) | 1,6 | 2,2 | 220 | 380 | 5 – 7 | 8 | 100 | 505 | 795 | 840 | 16-28 | 14-6 |
| SYMTH8-300/8 (FLOATER+CONTROL PANEL) | 2,2 | 3 | – | 380 | 8 – 10 | 8 | 100 | 505 | 800 | 840 | 20-28 | 17-10 |
| SYMH12-220/4 SYMTH12-220/4 (FLOATER+CONTROL PANEL) | 1,6 | 2,2 | 220 | 380 | 3 – 5 | 12 | 100 | 505 | 785 | 840 | 24-48 | 9-4 |
| SYMTH12-300/6 (FLOATER+CONTROL PANEL) | 2,2 | 3 | – | 380 | 5 – 7 | 12 | 100 | 505 | 790 | 840 | 24-38 | 14-9 |
Definition
These boosters are systems that enable water to reach comfortably in cases where the city mains water is insufficient, in high rise buildings, in residential units with tanks for water interruption and they operate completely automatically according to their intended use.
This type of boosters are self priming (4 meters) systems.
It is suitable for use in hygienic environments because its all surfaces in contact with water are completely stainless steel.
These pumps are manufactured at frequencies of 50 Hz and 60 Hz.
Usage Areas
These boosters are used in residential areas, industrial facilities, apartments, villas, schools, hospitals, factories and public housing, hotels, irrigation systems, treatment plants, heating and cooling systems.
SMINOX12A220/2
SMINOX12B220/2
SMINOX12C220/2
Techical Specifications
| MOTOR | PUMP | ||||||||||||||
| Type | KW | V Mono | V Tri | Hz | rpm | Hm | W mm | L mm | H mm | MANIFOLD INPUT | MANIFOLD OUTPUT | MAX FLOW m³/h | CAPACITY mss | NUMBER OF FLATS | NUMBER OF FLOORS |
| SMINOX12A220/2 | 1×1,6 | 220 | 380 | 50 | 2900 | 52 | 480 | 520 | 495 | 1¼ | 1¼ | 9 – 3 | 27 – 45 | 40 – 14 | 2 – 7 |
| SMINOX12B220/2 | 2×1,6 | 220 | 380 | 50 | 2900 | 52 | 850 | 520 | 700 | 1¼ | 2″ | 18 – 6 | 27 – 45 | 80 – 28 | 2 – 7 |
| SMINOX12C220/2 | 3×1,6 | 220 | 380 | 50 | 2900 | 52 | 1155 | 520 | 700 | 1¼ | 2″ | 27 – 9 | 27 – 45 | 120 – 42 | 2 – 7 |
| SMINOX12A300/3T | 1×2,2 | – | 380 | 50 | 2900 | 72 | 480 | 520 | 495 | 1¼ | 1¼ | 9 – 3 | 35 – 60 | 40 – 14 | 4 – 11 |
| SMINOX12B300/3T | 2×2,2 | – | 380 | 50 | 2900 | 72 | 850 | 520 | 700 | 1¼ | 2″ | 18 – 6 | 35 – 60 | 80 – 28 | 4 – 11 |
| SMINOX12C300/3T | 3×2,2 | – | 380 | 50 | 2900 | 72 | 1155 | 520 | 700 | 1¼ | 2″ | 27 – 9 | 35 – 60 | 120 – 42 | 4 – 11 |
Definition
These boosters are systems that enable water to reach comfortably in cases where the city mains water is insufficient, in high rise buildings, in residential units with tanks for water interruption and they operate completely automatically according to their intended use.
This type of boosters are self priming (4 meters) systems.
These pumps are manufactured at frequencies of 50 Hz and 60 Hz.
Usage Areas
These boosters are used in residential areas, industrial facilities, apartments, villas, schools, hospitals, factories and public housing, hotels, irrigation systems, treatment plants, heating and cooling systems.
SMKT A 750
SMKT B 750
SMKT C 750
Technical Specifications
| MOTOR | PUMP | |||||||||||||
| Type | KW | V | Hz | rpm | Hm | W mm | L mm | H mm | MANIFOLD INPUT | MANIFOLD OUTPUT | MAX FLOW m³/h | CAPACITY bar | NUMBER OF FLATS | NUMBER OF FLOORS |
| SMKTA550 | 1×4 | 380 | 50 | 2900 | 78 | 500 | 550 | 600 | 1½ | 1½ | 15-10 | 4.5-7 | 45 – 70 | 14 – 7 |
| SMKTB550 | 2×4 | 380 | 50 | 2900 | 78 | 950 | 790 | 700 | 1½ | 3 | 30-20 | 4.5-7 | 90 – 140 | 14 – 7 |
| SMKTC550 | 3×4 | 380 | 50 | 2900 | 78 | 1310 | 790 | 700 | 1½ | 3″ | 45-30 | 4.5-7 | 135 – 210 | 14 – 7 |
| SMKTA750 | 1×5,5 | 380 | 50 | 2900 | 87 | 500 | 550 | 600 | 1½ | 1½ | 15-10 | 5.5-8 | 45 – 70 | 17 – 10 |
| SMKTB750 | 2×5,5 | 380 | 50 | 2900 | 87 | 950 | 790 | 700 | 1½ | 3 | 30-20 | 5.5-8 | 90 – 140 | 17 – 10 |
| SMKTC750 | 3×5,5 | 380 | 50 | 2900 | 87 | 1310 | 790 | 700 | 1½ | 3 | 45-30 | 5.5-8 | 135 – 210 | 17 – 10 |
| SMKTA550/2 | 1×4 | 380 | 50 | 2900 | 58 | 500 | 550 | 600 | 2 | 2 | 25-10 | 3-5.5 | 45 – 115 | 10 – 3 |
| SMKTB550/2 | 2×4 | 380 | 50 | 2900 | 58 | 950 | 850 | 700 | 2 | 3 | 50-20 | 3-5.5 | 90 – 230 | 10 – 3 |
| SMKTC550/2 | 3×4 | 380 | 50 | 2900 | 58 | 1310 | 850 | 700 | 2 | 3 | 75-30 | 3-5.5 | 135 – 345 | 10 – 3 |
| SMKTA750/2 | 1×5,5 | 380 | 50 | 2900 | 68 | 500 | 550 | 600 | 2 | 2″ | 25-10 | 4-6 | 45 – 115 | 11 – 6 |
| SMKTB750/2 | 2×5,5 | 380 | 50 | 2900 | 68 | 950 | 850 | 700 | 2 | 3″ | 50-20 | 4-6 | 90 – 230 | 11 – 6 |
| SMKTC750/2 | 3×5,5 | 380 | 50 | 2900 | 68 | 1310 | 850 | 700 | 2 | 3″ | 75-30 | 4-6 | 135 – 345 | 11 – 6 |
Definition
These boosters are systems that enable water to reach comfortably in cases where the city mains water is insufficient, in high rise buildings, in residential units with for water interruption and they operate completely automatically according to their intended use.
These pumps are manufactured at frequencies of 50 Hz and 60 Hz.
Usage Areas
These boosters are used in residential areas, industrial facilities, apartments, villas, schools, hospitals, factories and public housing, hotels, irrigation systems, treatment plants, heating and cooling systems.
SHTP8 A
SHTP8 B
SHTP8 C
Techical Specifications
| MOTOR | PUMP | ||||||||||||
| TYPE | KW | V | Hz | rpm | W mm | L mm | H mm | MANIFOLD INPUT | MANIFOLD OUTPUT | MAX FLOW m³/h | CAPACITY mss | NUMBER OF FLATS | NUMBER OF FLOORS |
| SHTP8A-220/8 | 1×1,6 | 380 | 50 | 2900 | 360 | 405 | 867 | 1½ | 1½ | 5-4 | 5 – 6 | 18 – 24 | 11 – 8 |
| SHTP8B-220/8 | 2×1,6 | 380 | 50 | 2900 | 1000 | 750 | 867 | 2″ | 2″ | 10 – 8 | 5 – 6 | 36 – 48 | 11 – 8 |
| SHTP8C-220/8 | 3×1,6 | 380 | 50 | 2900 | 1300 | 750 | 867 | 2″ | 2″ | 15 – 12 | 5 -6 | 54 – 72 | 11 – 8 |
| SHTP8A-300/10 | 1×2,2 | 380 | 50 | 2900 | 360 | 405 | 927 | 1½ | 1½ | 5 – 4 | 6 – 7 | 18 – 24 | 14 – 11 |
| SHTP8B-300/10 | 2×2,2 | 380 | 50 | 2900 | 1000 | 750 | 927 | 2″ | 2″ | 10 – 8 | 6 – 7 | 36 – 48 | 14 – 11 |
| SHTP8C-300/10 | 3×2,2 | 380 | 50 | 2900 | 1300 | 750 | 927 | 2″ | 2″ | 15 – 12 | 6 – 7 | 54 – 72 | 14 – 11 |
| SHTP8A-400/12 | 1×3 | 380 | 50 | 2900 | 360 | 405 | 987 | 1½ | 1½ | 5 – 4 | 6.5-8 | 18 – 24 | 17 – 13 |
| SHTP8B-400/12 | 2×3 | 380 | 50 | 2900 | 1000 | 750 | 987 | 2″ | 2″ | 10 – 8 | 6.5-8 | 36 – 48 | 17 – 13 |
| SHTP8C-400/12 | 3×3 | 380 | 50 | 2900 | 1300 | 750 | 987 | 2″ | 2″ | 15 – 12 | 6.5-8 | 54 – 72 | 17 – 13 |
| SHTP16A-550/8 | 1×4 | 380 | 50 | 2900 | 360 | 405 | 960 | 1½ | 1½ | 9 – 5 | 5.5 – 7.5 | 35-48 | 11 – 7 |
| SHTP16B-550/8 | 2×4 | 380 | 50 | 2900 | 1000 | 800 | 960 | 3″ | 2½ | 18 – 10 | 5.5 – 7.5 | 70-96 | 11 – 7 |
| SHTP16C-550/8 | 3×4 | 380 | 50 | 2900 | 1300 | 800 | 960 | 3″ | 2½ | 27 – 15 | 5.5 – 7.5 | 105 – 144 | 11 – 7 |
| SHTP16A-550/10 | 1×4 | 380 | 50 | 2900 | 360 | 405 | 1020 | 1½ | 1½ | 10 – 5 | 7.5 – 10 | 24 – 48 | 23 – 15 |
| SHTP16B-550/10 | 2×4 | 380 | 50 | 2900 | 1000 | 800 | 1020 | 3″ | 2½ | 20 – 10 | 7.5 – 10 | 48 – 96 | 23 – 15 |
| SHTP16C-550/10 | 3×4 | 380 | 50 | 2900 | 1300 | 800 | 1020 | 3″ | 2½ | 30 – 15 | 7.5 – 10 | 72 – 144 | 23 – 15 |
| SHTP16A-750/12 | 1×5,5 | 380 | 50 | 2900 | 360 | 405 | 1081 | 1½ | 1½ | 10 – 6 | 8.5 – 12 | 28 – 48 | 28 – 19 |
| SHTP16B-750/12 | 2×5,5 | 380 | 50 | 2900 | 1000 | 800 | 1081 | 3″ | 2½ | 20 – 12 | 8.5 – 12 | 56 – 96 | 28 – 19 |
| SHTP16C-750/12 | 3×5,5 | 380 | 50 | 2900 | 1300 | 800 | 1081 | 3″ | 2½ | 30 – 18 | 8.5 – 12 | 85 – 144 | 28 – 19 |
| SHTP16A-750/14 | 1×5,5 | 380 | 50 | 2900 | 360 | 405 | 1042 | 1½ | 1½ | 10 -7 | 9.5 – 13 | 32 – 48 | 32 – 22 |
| SHTP16B-750/14 | 2×5,5 | 380 | 50 | 2900 | 1000 | 800 | 1042 | 3″ | 2½ | 20 – 14 | 9.5 – 13 | 64 – 96 | 32 – 22 |
| SHTP16C 750/14 | 3×5.5 | 380 | 50 | 2900 | 1300 | 800 | 1042 | 3″ | 2½ | 30-21 | 9.5 – 13 | 96-44 | 32-22 |
Definition
These boosters are systems that enable water to reach comfortably in cases where the city mains water is insufficient, in high rise buildings, in residential units with tanks for water interruption and they operate completely automatically according to their intended use.
These pumps are manufactured at frequencies of 50 Hz and 60 Hz.
Usage Areas
These boosters are used in residential areas, industrial facilities, apartments, villas, schools, hospitals, factories and public housing, hotels, irrigation systems, treatment plants, heating and cooling systems.
SHTPD8 A
SHTPD8 B
SHTPD8 C
Techical Specifications
| MOTOR | PUMP | ||||||||||||
| TYPE | KW | V | Hz | rpm | W mm | L mm | H mm | MANIFOLD INPUT | MANIFOLD OUTPUT | MAX FLOW m³/h | CAPACITY mss | NUMBER OF FLATS | NUMBER OF FLOORS |
| SHTPD8A-220/8 | 1×1,6 | 380 | 50 | 2900 | 360 | 506 | 9+8 | 1½ | 1½ | 5-4 | 5-6 | 18 – 24 | 11 – 8 |
| SHTPD8B-220/8 | 2×1,6 | 380 | 50 | 2900 | 1000 | 750 | 867 | 2″ | 2″ | 10-8 | 5-6 | 36 – 48 | 11 – 8 |
| SHTPD8C-220/8 | 3×1,6 | 380 | 50 | 2900 | 1300 | 750 | 867 | 2″ | 2″ | 12 – 15 | 5-6 | 54 – 72 | 11 – 8 |
| SHTPD8A-300/10 | 1×2,2 | 380 | 50 | 2900 | 360 | 405 | 927 | 1½ | 1½ | 5-4 | 6-7 | 18 – 24 | 14 – 11 |
| SHTPD8B-300/10 | 2×2,2 | 380 | 50 | 2900 | 1000 | 750 | 927 | 2″ | 2″ | 10-8 | 6-7 | 36 – 48 | 14 – 11 |
| SHTPD8C-300/10 | 3×2,2 | 380 | 50 | 2900 | 1300 | 750 | 927 | 2″ | 2″ | 15-12 | 6-7 | 54 – 72 | 14 – 11 |
| SHTPD8A-400/12 | 1×3 | 380 | 50 | 2900 | 360 | 405 | 987 | 1½ | 1½ | 5-4 | 6.5-8 | 18 – 24 | 17 – 13 |
| SHTPD8B-400/12 | 2×3 | 380 | 50 | 2900 | 1000 | 750 | 987 | 2″ | 2″ | 10-8 | 6.5-8 | 36 – 48 | 17 – 13 |
| SHTPD8C-400/12 | 3×3 | 380 | 50 | 2900 | 1300 | 750 | 987 | 2″ | 2″ | 15-12 | 6.5-8 | 54 – 72 | 17 – 13 |
| SHTPD16A-550/8 | 1×4 | 380 | 50 | 2900 | 360 | 405 | 960 | 1½ | 1½ | 10-2.5 | 4.5-6 | 35– 48 | 11 – 7 |
| SHTPD16B-550/8 | 2×4 | 380 | 50 | 2900 | 1000 | 800 | 960 | 3″ | 2½ | 20-5 | 4.5-6 | 70– 96 | 11 – 7 |
| SHTPD16C-550/8 | 3×4 | 380 | 50 | 2900 | 1300 | 800 | 960 | 3″ | 2½ | 30-7.5 | 4.5-6 | 105– 144 | 11 – 7 |
| SHTPD16A-550/10 | 1×4 | 380 | 50 | 2900 | 360 | 405 | 1020 | 1½ | 1½ | 10-5 | 7.5-10 | 24 – 48 | 23 – 15 |
| SHTPD16B-550/10 | 2×4 | 380 | 50 | 2900 | 1000 | 800 | 1020 | 3″ | 2½ | 20-10 | 7.5-10 | 48 – 96 | 23 – 15 |
| SHTPD16C-550/10 | 3×4 | 380 | 50 | 2900 | 1300 | 800 | 1020 | 3″ | 2½ | 30-15 | 7.5-10 | 72 – 144 | 23 – 15 |
| SHTPD16A-750/12 | 1×5,5 | 380 | 50 | 2900 | 360 | 405 | 1081 | 1½ | 1½ | 10-6 | 8.5-12 | 28 – 48 | 28 – 19 |
| SHTPD16B-750/12 | 2×5,5 | 380 | 50 | 2900 | 1000 | 800 | 1081 | 3″ | 2½ | 20-12 | 8.5-12 | 56 – 96 | 28 – 19 |
| SHTPD16C-750/12 | 3×5,5 | 380 | 50 | 2900 | 1300 | 800 | 1081 | 3″ | 2½ | 30-18 | 8.5-12 | 85 – 144 | 28 – 19 |
| SHTPD16A-750/14 | 1×5,5 | 380 | 50 | 2900 | 360 | 405 | 1042 | 1½ | 1½ | 10-7 | 9.5-13 | 32 – 48 | 32 – 22 |
| SHTPD16B-750/14 | 2×5,5 | 380 | 50 | 2900 | 1000 | 800 | 1042 | 3″ | 2½ | 20-14 | 9.5-13 | 64 – 96 | 32 – 22 |
| SHTPD16C-750/14 | 3×5,5 | 380 | 50 | 2900 | 1300 | 800 | 1042 | 3″ | 2½ | 30-21 | 9.5-13 | 96 – 144 | 32 – 22 |
Definition
Booster is systems that allow water to reach comfortably and the way of operation is completely automatic according to the intended use in cases where the city mains is insufficient, in high rise buildings, in residential units with tanks for water interruption.
These pumps are manufactured at frequencies of 50 Hz and 60 Hz.
Usage Areas
These booster sets are used in residential areas, industrial facilities, apartments, villas, schools, hospitals, factories and public housing, hotels, irrigation systems, treatment plants, heating and cooling systems.
SHT6 A
SHT6 B
SHT6 C
Techical Specifications
| MOTOR | PUMP | |||||||||||||
| TYPE | KW | V Mono | V Tri | Hz | rpm | W mm | L mm | H mm | MANIFOLD INPUT | MANIFOLD OUTPUT | MAX FLOW m³/h | CAPACITY mss | NUMBER OF FLATS | NUMBER OF FLOORS |
| SHT6A-100/6 | 1×0,75 | 220 | 380 | 50 | 2900 | 340 | 290 | 570 | 1¼ | 1″ | 2,5 – 4,0 | 42 – 25 | 12 – 16 | 6-3 |
| SHT6B-100/6 | 2×0,75 | 220 | 380 | 50 | 2900 | 940 | 465 | 820 | 2″ | 2″ | 5,0 – 8,0 | 42 – 25 | 24 – 32 | 6-3 |
| SHT6C-100/6 | 3×0,75 | 220 | 380 | 50 | 2900 | 1190 | 465 | 820 | 2″ | 2″ | 7,5 – 12 | 42 – 25 | 36 – 48 | 6-3 |
| SHT6A-150/8 | 1×1,1 | 220 | 380 | 50 | 2900 | 340 | 290 | 570 | 1¼ | 1″ | 2,5 – 4,2 | 50 – 30 | 12 – 18 | 9 – 4 |
| SHT6B-150/8 | 2×1,1 | 220 | 380 | 50 | 2900 | 940 | 465 | 820 | 2″ | 2″ | 5,0 – 8,4 | 50 – 30 | 24 – 36 | 9 – 4 |
| SHT6C-150/8 | 3×1,1 | 220 | 380 | 50 | 2900 | 1190 | 465 | 820 | 2″ | 2″ | 7,5 – 12,6 | 50 – 30 | 36-54 | 9 – 4 |
| SHT6A-180/10 | 1×1,35 | – | 380 | 50 | 2900 | 340 | 290 | 610 | 1¼ | 1″ | 2,6 – 3,4 | 60 – 50 | 12 – 18 | 12 – 8 |
| SHT6B-180/10 | 2×1,35 | – | 380 | 50 | 2900 | 940 | 465 | 820 | 2″ | 2″ | 5,2 – 6,8 | 60 – 50 | 24 – 36 | 12 – 8 |
| SHT6C-180/10 | 3×1,35 | – | 380 | 50 | 2900 | 1190 | 465 | 820 | 2″ | 2″ | 7,6 – 10,2 | 60 – 50 | 36 – 54 | 12 – 8 |
Definition
Booster is systems that allow water to reach comfortably and the way of operation is completely automatic according to the intended use in cases where the city mains is insufficient, in high rise buildings, in residential units with tanks for water interruption.
These pumps are manufactured at frequencies of 50 Hz and 60 Hz.
Usage Areas
These booster sets are used in residential areas, industrial facilities, apartments, villas, schools, hospitals, factories and public housing, hotels, irrigation systems, treatment plants, heating and cooling systems.
SHT8 A
SHT8 B
SHT8 C
Techical Specifications
| MOTOR | PUMP | |||||||||||||
| Type | KW | V Mono | V Tri | Hz | rpm | W mm | L mm | H mm | MANIFOLD INPUT | MANIFOLD OUTPUT | MAX FLOW m³/h | CAPACITY mss | NUMBER OF FLATS | NUMBER OF FLOORS |
| SHT8A-220/6 | 1×1,6 | 220 | 380 | 50 | 2900 | 350 | 290 | 610 | 1¼ | 1¼ | 3,5 – 6 | 70 – 40 | 16 – 28 | 14 – 6 |
| SHT8B-220/6 | 2×1,6 | 220 | 380 | 50 | 2900 | 940 | 465 | 820 | 2″ | 2″ | 7 – 12 | 70 – 40 | 32 – 56 | 14 – 6 |
| SHT8C-220/6 | 3×1,6 | 220 | 380 | 50 | 2900 | 1190 | 465 | 820 | 2″ | 2″ | 10,5 – 18 | 70 – 40 | 48 – 84 | 14 – 6 |
| SHT8A-300/8 | 1×2,2 | – | 380 | 50 | 2900 | 350 | 290 | 610 | 1¼ | 1¼ | 4 – 5,5 | 80 – 60 | 20-28 | 17 – 10 |
| SHT8B-300/8 | 2×2,2 | – | 380 | 50 | 2900 | 940 | 465 | 820 | 2″ | 2″ | 8 – 11 | 80 – 60 | 40-56 | 17 – 10 |
| SHT8C-300/8 | 3×2,2 | – | 380 | 50 | 2900 | 1190 | 465 | 820 | 2″ | 2″ | 12 – 16 | 80 – 60 | 60-84 | 17 – 10 |
| SHT8A-400/10 | 1×3 | – | 380 | 50 | 2900 | 350 | 290 | 640 | 1¼ | 1¼ | 4 – 5 | 90 – 80 | 20– 28 | 20 – 12 |
| SHT8B-400/10 | 2×3 | – | 380 | 50 | 2900 | 940 | 465 | 820 | 2″ | 2″ | 8 – 10 | 90 – 80 | 40 -56 | 20 – 12 |
| SHT8C-400/10 | 3×3 | – | 380 | 50 | 2900 | 1190 | 465 | 820 | 2″ | 2″ | 12 – 15 | 90 – 80 | 60 – 84 | 20 – 12 |
Definition
Booster is systems that allow water to reach comfortably and the way of operation is completely automatic according to the intended use in cases where the city mains is insufficient, in high rise buildings, in residential units with tanks for water interruption.
These pumps are manufactured at frequencies of 50 Hz and 60 Hz.
Usage Areas
These booster sets are used in residential areas, industrial facilities, apartments, villas, schools, hospitals, factories and public housing, hotels, irrigation systems, treatment plants, heating and cooling systems.
SHT12 A
SHT12 B
SHT12 C
Techical Specifications
| MOTOR | PUMP | |||||||||||||
| TYPE | KW | V Mono | V Tri | Hz | rpm | W mm | L mm | H mm | MANIFOLD INPUT | MANIFOLD OUTPUT | MAX FLOW m³/h | CAPACITY mss | NUMBER OF FLATS | NUMBER OF FLOORS |
| SHT12A-220/4 | 1×1,6 | 220 | 380 | 50 | 2900 | 350 | 290 | 580 | 1¼ | 1¼ | 5 – 9 | 50 – 30 | 24 – 48 | 9 – 4 |
| SHT12B-220/4 | 2×1,6 | 220 | 380 | 50 | 2900 | 940 | 465 | 820 | 2″ | 2″ | 10 – 18 | 50 – 30 | 48– 96 | 9 – 4 |
| SHT12C-220/4 | 3×1,6 | 220 | 380 | 50 | 2900 | 1190 | 465 | 820 | 2″ | 2″ | 15 – 27 | 50 – 30 | 72 – 144 | 9 – 4 |
| SHT12A-300/6 | 1×2,2 | – | 380 | 50 | 2900 | 350 | 290 | 580 | 1¼ | 1¼ | 4 – 7,5 | 70 – 50 | 24-38 | 14 – 9 |
| SHT12B-300/6 | 2×2,2 | – | 380 | 50 | 2900 | 940 | 465 | 820 | 2″ | 2″ | 8 – 15 | 70 – 50 | 48-76 | 14 – 9 |
| SHT12C-300/6 | 3×2,2 | – | 380 | 50 | 2900 | 1190 | 465 | 820 | 2″ | 2″ | 12 – 22,5 | 70 – 50 | 72-114 | 14 – 9 |
| SHT12A-400/7 | 1×3 | – | 380 | 50 | 2900 | 350 | 290 | 585 | 1¼ | 1¼ | 3,5 – 7 | 80 – 70 | 26-34 | 17 – 14 |
| SHT12B-400/7 | 2×3 | – | 380 | 50 | 2900 | 940 | 465 | 585 | 2″ | 2″ | 7 – 14 | 80 – 70 | 52-68 | 17 – 14 |
| SHT12C-400/7 | 3×3 | – | 380 | 50 | 2900 | 1190 | 465 | 585 | 2″ | 2″ | 10 – 21 | 80 – 70 | 78-102 | 17 – 14 |
Definition
Booster is systems that allow water to reach comfortably and the way of operation is completely automatic according to the intended use in cases where the city mains is insufficient, in high rise buildings, in residential units with tanks for water interruption.
These pumps are manufactured at frequencies of 50 Hz and 60 Hz.
Usage Areas
These booster sets are used in residential areas, industrial facilities, apartments, villas, schools, hospitals, factories and public housing, hotels, irrigation systems, treatment plants, heating and cooling systems.
SHT16 A
SHT16 B
SHT16 C
Techical Specifications
| MOTOR | PUMP | ||||||||||||
| TYPE | KW | V | Hz | rpm | W mm | L mm | H mm | MANIFOLD INPUT | MANIFOLD OUTPUT | MAX FLOW m³/h | CAPACITY mss | NUMBER OF FLATS | NUMBER OF FLOORS |
| SHT16A-550/4 | 1×4 | 380 | 50 | 2900 | 370 | 330 | 620 | 1½ | 1¼ | 4 – 16 | 70 – 40 | 20-48 | 13-9 |
| SHT16B-550/4 | 2×4 | 380 | 50 | 2900 | 940 | 550 | 820 | 3″ | 2½ | 8 – 32 | 70 – 40 | 40-96 | 13-9 |
| SHT16C-550/4 | 3×4 | 380 | 50 | 2900 | 1190 | 550 | 820 | 3″ | 2½ | 12 – 48 | 70 – 40 | 60-144 | 13-9 |
| SHT16A-550/5 | 1×4 | 380 | 50 | 2900 | 370 | 330 | 660 | 1½ | 1¼ | 8 – 11 | 90 – 60 | 40-54 | 14 – 11 |
| SHT16B-550/5 | 2×4 | 380 | 50 | 2900 | 940 | 550 | 820 | 3″ | 2½ | 16 – 22 | 90 – 60 | 80-108 | 14 – 11 |
| SHT16C-550/5 | 3×4 | 380 | 50 | 2900 | 1190 | 550 | 820 | 3″ | 2½ | 24 – 33 | 90 – 60 | 120-162 | 14 – 11 |
| SHT16A-750/6 | 1×5,5 | 380 | 50 | 2900 | 370 | 330 | 700 | 1½ | 1¼ | 7 – 14 | 100 – 80 | 34 – 64 | 20-10 |
| SHT16B-750/6 | 2×5,5 | 380 | 50 | 2900 | 940 | 550 | 820 | 3″ | 2½ | 14 – 28 | 100 – 80 | 68 – 128 | 20-10 |
| SHT16C-750/6 | 3×5,5 | 380 | 50 | 2900 | 1190 | 550 | 820 | 3″ | 2½ | 21 – 42 | 100 – 80 | 102-192 | 20-10 |
| SHT16A-750/7 | 1×5,5 | 380 | 50 | 2900 | 370 | 330 | 740 | 1½ | 1¼ | 6 – 13 | 110 – 90 | 32– 60 | 25 – 15 |
| SHT16B-750/7 | 2×5,5 | 380 | 50 | 2900 | 940 | 550 | 820 | 3″ | 2½ | 12 – 26 | 110 – 90 | 64 – 120 | 25 – 15 |
| SHT16C-750/7 | 3×5,5 | 380 | 50 | 2900 | 1190 | 550 | 820 | 3″ | 2½ | 18 – 39 | 110 – 90 | 96 – 180 | 25 – 15 |
| SHT16A-850/8 | 1×6,3 | 380 | 50 | 2900 | 370 | 330 | 740 | 1½ | 1¼ | 6 – 13 | 120 – 100 | 32 – 60 | 28 – 18 |
| SHT16B-850/8 | 2×6,3 | 380 | 50 | 2900 | 940 | 550 | 820 | 3″ | 2½ | 12 – 26 | 120 – 100 | 64– 120 | 28 – 18 |
| SHT16C-850/8 | 3×6,3 | 380 | 50 | 2900 | 1190 | 550 | 820 | 3″ | 2½ | 18 – 39 | 120 – 100 | 96– 184 | 28 – 18 |
Definition
Booster is systems that allow water to reach comfortably and the way of operation is completely automatic according to the intended use in cases where the city mains is insufficient, in high rise buildings, in residential units with tanks for water interruption.
These pumps are manufactured at frequencies of 50 Hz and 60 Hz.
Usage Areas
These booster sets are used in residential areas, industrial facilities, apartments, villas, schools, hospitals, factories and public housing, hotels, irrigation systems, treatment plants, heating and cooling systems.
SHT24 A
SHT24 B
SHT24 C
Techical Specifications
| MOTOR | PUMP | ||||||||||||
| TYPE | KW | V | Hz | rpm | W mm | L mm | H mm | MANIFOLD INPUT | MANIFOLD OUTPUT | MAX FLOW m³/h | CAPACITY mss | NUMBER OF FLATS | NUMBER OF FLOORS |
| SHT24A-750/4 | 1×5,5 | 380 | 50 | 2900 | 750 | 517 | 1065 | 2″ | 1½ | 9 – 20 | 50 – 30 | 42 – 95 | 8 – 3 |
| SHT24B-750/4 | 2×5,5 | 380 | 50 | 2900 | 1105 | 567 | 1065 | 3″ | 2½ | 18 – 40 | 50 – 30 | 84 – 190 | 8 – 3 |
| SHT24C-750/4 | 3×5,5 | 380 | 50 | 2900 | 1450 | 717 | 1065 | DN 100 | 3″ | 27 – 60 | 50 – 30 | 126 – 285 | 8 – 3 |
| SHT24A-750/5 | 1×5,5 | 380 | 50 | 2900 | 750 | 517 | 1115 | 2″ | 1½ | 10 – 19 | 60 – 40 | 48 – 89 | 11 – 6 |
| SHT24B-750/5 | 2×5,5 | 380 | 50 | 2900 | 1105 | 567 | 1115 | 3″ | 2½ | 20 – 38 | 60 – 40 | 96 – 178 | 11 – 6 |
| SHT24C-750/5 | 3×5,5 | 380 | 50 | 2900 | 1450 | 717 | 1115 | DN 100 | 3″ | 30 – 57 | 60 – 40 | 144 – 267 | 11 – 6 |
| SHT24A-750/6 | 1×5,5 | 380 | 50 | 2900 | 750 | 517 | 1165 | 2″ | 1½ | 11 – 18 | 70 – 50 | 52 – 85 | 14 – 8 |
| SHT24B-750/6 | 2×5,5 | 380 | 50 | 2900 | 1105 | 567 | 1165 | 3″ | 2½ | 22 – 36 | 70 – 50 | 104 – 170 | 14 – 8 |
| SHT24C-750/6 | 3×5,5 | 380 | 50 | 2900 | 1450 | 717 | 1165 | DN 100 | 3″ | 33 – 54 | 70 – 50 | 156 – 255 | 14 – 8 |
| SHT24A-1000/7 | 1×7,5 | 380 | 50 | 2900 | 750 | 517 | 1215 | 2″ | 1½ | 7 – 17 | 90 – 65 | 33 – 80 | 20 – 12 |
| SHT24B-1000/7 | 2×7,5 | 380 | 50 | 2900 | 1105 | 567 | 1215 | 3″ | 2½ | 14 – 37 | 90 – 65 | 66 – 160 | 20 – 12 |
| SHT24C-1000/7 | 3×7,5 | 380 | 50 | 2900 | 1450 | 717 | 1215 | DN 100 | 3″ | 21 – 51 | 90 – 65 | 99 – 240 | 20 – 12 |
| SHT24A-1000/8 | 1×7,5 | 380 | 50 | 2900 | 750 | 517 | 1265 | 2″ | 1½ | 9 – 16 | 100 – 80 | 42 – 76 | 23 – 17 |
| SHT24B-1000/8 | 2×7,5 | 380 | 50 | 2900 | 1105 | 567 | 1265 | 3″ | 2½ | 18 – 32 | 100 – 80 | 84 – 152 | 23 – 17 |
| SHT24C-1000/8 | 3×7,5 | 380 | 50 | 2900 | 1450 | 717 | 1265 | DN 100 | 3″ | 27 – 47 | 100 – 80 | 126 – 228 | 23 – 17 |
Definition
Booster is systems that allow water to reach comfortably and the way of operation is completely automatic according to the intended use in cases where the city mains is insufficient, in high rise buildings, in residential units with tanks for water interruption.
These pumps are manufactured at frequencies of 50 Hz and 60 Hz.
Usage Areas
These booster sets are used in residential areas, industrial facilities, apartments, villas, schools, hospitals, factories and public housing, hotels, irrigation systems, treatment plants, heating and cooling systems.
SHT34 A
SHT34 B
SHT34 C
Techical Specifications
| MOTOR | PUMP | ||||||||||||
| TYPE | KW | V | Hz | rpm | W mm | L mm | H mm | MANIFOLD INPUT | MANIFOLD OUTPUT | MAX FLOW m³/h | CAPACITY mss | NUMBER OF FLATS | NUMBER OF FLOORS |
| SHT34A-750/4 | 1×5,5 | 380 | 50 | 2900 | 750 | 517 | 1065 | 2″ | 1½ | 16 – 29 | 60 – 40 | 76 – 136 | 11 – 6 |
| SHT34B-750/4 | 2×5,5 | 380 | 50 | 2900 | 1105 | 567 | 1065 | 3″ | 2½ | 32 – 58 | 60 – 40 | 152 – 272 | 11 – 6 |
| SHT34C-750/4 | 3×5,5 | 380 | 50 | 2900 | 1450 | 717 | 1065 | DN 100 | 3″ | 48 – 87 | 60 – 40 | 228 – 408 | 11 – 6 |
| SHT34A-1000/5 | 1×7,5 | 380 | 50 | 2900 | 750 | 517 | 1115 | 2″ | 1½ | 12 – 27 | 80 – 60 | 56 – 128 | 17 – 11 |
| SHT34B-1000/5 | 2×7,5 | 380 | 50 | 2900 | 1105 | 567 | 1115 | 3″ | 2½ | 36 – 54 | 80 – 60 | 112 – 256 | 17 – 11 |
| SHT34C-1000/5 | 3×7,5 | 380 | 50 | 2900 | 1405 | 717 | 1115 | DN 100 | 3″ | 36 – 81 | 80 – 60 | 168 – 384 | 17 – 11 |
| SHT34A-1500/6 | 1×11 | 380 | 50 | 2900 | 750 | 517 | 1165 | 2″ | 1½ | 16 – 28 | 90 – 70 | 76 – 130 | 20 – 14 |
| SHT34B-1500/6 | 2×11 | 380 | 50 | 2900 | 1105 | 567 | 1165 | 3″ | 2½ | 32 – 56 | 90 – 70 | 152 – 260 | 20 – 14 |
| SHT34C-1500/6 | 3×11 | 380 | 50 | 2900 | 1450 | 717 | 1165 | DN 100 | 3″ | 48 – 84 | 90 – 70 | 228 – 390 | 20 – 14 |
| SHT34A-1500/7 | 1×11 | 380 | 50 | 2900 | 750 | 517 | 1215 | 2″ | 1½ | 22 – 30 | 100 – 80 | 104 – 140 | 23 – 17 |
| SHT34B-1500/7 | 2×11 | 380 | 50 | 2900 | 1105 | 567 | 1215 | 3″ | 2½ | 44 – 60 | 100 – 80 | 210 – 280 | 23 – 17 |
| SHT34C-1500/7 | 3×11 | 380 | 50 | 2900 | 1450 | 717 | 1215 | DN 100 | 3″ | 66 – 90 | 100 – 80 | 312 – 420 | 23 – 17 |
Definition
Booster is systems that allow water to reach comfortably and the way of operation is completely automatic according to the intended use in cases where the city mains is insufficient, in high rise buildings, in residential units with tanks for water interruption.
These pumps are manufactured at frequencies of 50 Hz and 60 Hz.
Usage Areas
These booster sets are used in residential areas, industrial facilities, apartments, villas, schools, hospitals, factories and public housing, hotels, irrigation systems, treatment plants, heating and cooling systems.
SHT44 A
SHT44 B
SHT44 C
Techical Specifications
| MOTOR | PUMP | ||||||||||||
| Type | KW | V | Hz | Rpm | W mm | L mm | H mm | MANIFOLD INPUT | MANIFOLD OUTPUT | MAX FLOW m³/h | CAPACITY mss | NUMBER OF FLATS | NUMBER OF FLOORS |
| SHT44A 1500/5 | 1×11 | 380 | 50 | 2900 | 490 | 685 | 1200 | 3″ | 2½ | 36-25 | 5-7 | 120-170 | 14-8 |
| SHT44B 1500/5 | 2×11 | 380 | 50 | 2900 | 1335 | 805 | 1225 | DN 100 | 3″ | 72-50 | 5-7 | 240-340 | 14-8 |
| SHT44C 1500/5 | 3×11 | 380 | 50 | 2900 | 1735 | 830 | 1225 | DN 125 | DN 100 | 108-75 | 5-7 | 360-510 | 14-8 |
| SHT44A 1500/6 | 1×11 | 380 | 50 | 2900 | 490 | 685 | 1250 | 3″ | 2½ | 33-23 | 7-9 | 112-155 | 20-14 |
| SHT44B 1500/6 | 2×11 | 380 | 50 | 2900 | 1335 | 805 | 1270 | DN 100 | 3″ | 66-46 | 7-9 | 220-310 | 20-14 |
| SHT44C 1500/6 | 3×11 | 380 | 50 | 2900 | 1735 | 830 | 1270 | DN 125 | DN 100 | 98-69 | 7-9 | 330-465 | 20-14 |
| SHT44A 2000/7 | 1×15 | 380 | 50 | 2900 | 720 | 685 | 1400 | 3″ | 2½ | 33-26 | 8-10 | 124-154 | 23-17 |
| SHT44B 2000/7 | 2×15 | 380 | 50 | 2900 | 1335 | 805 | 1425 | DN 100 | 3″ | 66-52 | 8-10 | 248-310 | 23-17 |
| SHT44C 2000/7 | 3×15 | 380 | 50 | 2900 | 1735 | 830 | 1425 | DN 125 | DN 100 | 99-78 | 8-10 | 372-465 | 23-17 |
| SHT44A 2000/8 | 1×15 | 380 | 50 | 2900 | 720 | 685 | 1450 | 3″ | 2½ | 32-24 | 10-12 | 114-152 | 28-23 |
| SHT44B 2000/8 | 2×15 | 380 | 50 | 2900 | 1335 | 805 | 1470 | DN 100 | 3″ | 64-48 | 10-12 | 228-304 | 28-23 |
| SHT44C 2000/8 | 3×15 | 380 | 50 | 2900 | 1735 | 830 | 1470 | DN 125 | DN 100 | 96-72 | 10-12 | 342-456 | 28-23 |
Definition
Booster is systems that allow water to reach comfortably and the way of operation is completely automatic according to the intended use in cases where the city mains is insufficient, in high rise buildings, in residential units with tanks for water interruption.
These pumps are manufactured at frequencies of 50 Hz and 60 Hz.
Usage Areas
These booster sets are used in residential areas, industrial facilities, apartments, villas, schools, hospitals, factories and public housing, hotels, irrigation systems, treatment plants, heating and cooling systems.
SHT60 A
SHT60 B
SHT60 C
Technical Specifications
| MOTOR | PUMP | ||||||||||||
| Type | KW | V | Hz | Rpm | W mm | L mm | H mm | MANIFOLD INPUT | MANIFOLD OUTPUT | MAX FLOW m³/h | CAPACITY mss | NUMBER OF FLATS | NUMBER OF FLOORS |
| SHT60A 2000/4 | 1×15 | 380 | 50 | 2900 | 720 | 685 | 1330 | 3″ | 2½ | 56-38 | 5-7 | 182-260 | 14-8 |
| SHT60B 2000/4 | 2×15 | 380 | 50 | 2900 | 1335 | 830 | 1350 | DN 125 | DN 100 | 112-76 | 5-7 | 364-520 | 14-8 |
| SHT60C 2000/4 | 3×15 | 380 | 50 | 2900 | 1735 | 860 | 1350 | DN 150 | DN 125 | 168-114 | 5-7 | 546-780 | 14-8 |
| SHT60A 2000/5 | 1×15 | 380 | 50 | 2900 | 720 | 685 | 1395 | 3″ | 2½ | 52-34 | 7-9 | 165-240 | 20-14 |
| SHT60B 2000/5 | 2×15 | 380 | 50 | 2900 | 1335 | 830 | 1415 | DN 125 | DN 100 | 104-68 | 7-9 | 330-480 | 20-14 |
| SHT60C 2000/5 | 3×15 | 380 | 50 | 2900 | 1735 | 860 | 1415 | DN 150 | DN 125 | 156-102 | 7-9 | 495-720 | 20-14 |
| SHT60A 2500/6 | 1×18.5 | 380 | 50 | 2900 | 720 | 685 | 1460 | 3″ | 2½ | 48-33 | 9-11 | 155-230 | 26-20 |
| SHT60B 2500/6 | 2×18.5 | 380 | 50 | 2900 | 1335 | 830 | 1480 | DN 125 | DN 100 | 96-66 | 9-11 | 310-460 | 26-20 |
| SHT60C 2500/6 | 3×18.5 | 380 | 50 | 2900 | 1735 | 860 | 1480 | DN 150 | DN 125 | 144-99 | 9-11 | 465-690 | 26-20 |
Definition
Booster is systems that allow water to reach comfortably and the way of operation is completely automatic according to the intended use in cases where the city mains is insufficient, in high rise buildings, in residential units with tanks for water interruption.
These pumps are manufactured at frequencies of 50 Hz and 60 Hz.
Usage Areas
These booster sets are used in residential areas, industrial facilities, apartments, villas, schools, hospitals, factories and public housing, hotels, irrigation systems, treatment plants, heating and cooling systems.
SHT32 A
SHT32 B
SHT32 C
Techical Specifications
| MOTOR | PUMP | ||||||||||
| TYPE | KW | V | Hz | rpm | W mm | L mm | H mm | MANIFOLD INPUT | MANIFOLD OUTPUT | MAX FLOW m³/h | CAPACITY mss |
| SHT 32/2 A | 1×3 | 380 | 50 | 2900 | 335 | 800 | 1119 | 1½ | 1¼ | 13 – 19 | 40 – 20 |
| SHT 32/2 B | 2×3 | 380 | 50 | 2900 | 675 | 1415 | 1119 | 3″ | 2½ | 26 – 38 | 40 – 20 |
| SHT 32/2 C | 3×3 | 380 | 50 | 2900 | 1106 | 1415 | 1119 | 4″ | 3″ | 39 – 57 | 40 – 20 |
| SHT 32/3 A | 1×4 | 380 | 50 | 2900 | 335 | 800 | 1209 | 1½ | 1¼ | 10 – 18 | 70 – 30 |
| SHT 32/3 B | 2×4 | 380 | 50 | 2900 | 675 | 1015 | 1209 | 4″ | 3″ | 30 – 54 | 70 – 30 |
| SHT 32/3 C | 3×4 | 380 | 50 | 2900 | 1106 | 1015 | 1209 | 4″ | 3″ | 30 – 54 | 70 – 30 |
| SHT 32/4 A | 1×5,5 | 380 | 50 | 2900 | 335 | 800 | 1274 | 1½ | 1¼ | 10 – 19 | 90 – 60 |
| SHT 32/4 B | 2×5,5 | 380 | 50 | 2900 | 675 | 1015 | 1274 | 3″ | 2½ | 20 – 38 | 90 – 60 |
| SHT 32/4 C | 3×5,5 | 380 | 50 | 2900 | 1106 | 1015 | 1274 | 4″ | 3″ | 30 – 57 | 90 – 60 |
| SHT 32/5 A | 1×7,5 | 380 | 50 | 2900 | 335 | 800 | 1285 | 1½ | 1¼ | 12 – 17 | 110 – 70 |
| SHT 32/5 B | 2×7,5 | 380 | 50 | 2900 | 675 | 1015 | 1385 | 3″ | 2½ | 24 – 34 | 110 – 70 |
| SHT 32/5 C | 3×7,5 | 380 | 50 | 2900 | 1106 | 1015 | 1385 | 4″ | 3″ | 36 – 51 | 110 – 70 |
| SHT 32/6 A | 1×11 | 380 | 50 | 2900 | 335 | 800 | 1479 | 1½ | 1¼ | 12 – 18 | 130 – 90 |
| SHT 32/6 B | 2×11 | 380 | 50 | 2900 | 675 | 1015 | 1479 | 3″ | 2½ | 24 – 36 | 130 – 90 |
| SHT 32/6 C | 3×11 | 380 | 50 | 2900 | 1106 | 1014 | 1479 | 4″ | 3″ | 36 – 54 | 130 – 90 |
Definition
Booster is systems that allow water to reach comfortably and the way of operation is completely automatic according to the intended use in cases where the city mains is insufficient, in high rise buildings, in residential units with tanks for water interruption.
These pumps are manufactured at frequencies of 50 Hz and 60 Hz.
Usage Areas
These booster sets are used in residential areas, industrial facilities, apartments, villas, schools, hospitals, factories and public housing, hotels, irrigation systems, treatment plants, heating and cooling systems.
SHT40 A
SHT40 B
SHT40 C
Techical Specifications
| MOTOR | PUMP | ||||||||||
| TYPE | KW | V | Hz | rpm | W mm | L mm | H mm | MANIFOLD INPUT | MANIFOLD OUTPUT | MAX FLOW m³/h | CAPACITY mss |
| SHT40/2 A | 1×7,5 | 380 | 50 | 2900 | 335 | 800 | 1255 | 2″ | 1½ | 32 – 38 | 40 – 30 |
| SHT40/2 B | 2×7,5 | 380 | 50 | 2900 | 675 | 1415 | 1255 | 3″ | 3″ | 64 – 76 | 40 – 30 |
| SHT40/2 C | 3×7,5 | 380 | 50 | 2900 | 1106 | 1415 | 1255 | 5″ | 4″ | 96 – 114 | 40 – 30 |
| SHT40/3 A | 1×11 | 380 | 50 | 2900 | 335 | 800 | 1356 | 2″ | 1½ | 20 – 33 | 80 – 60 |
| SHT40/3 B | 2×11 | 380 | 50 | 2900 | 375 | 1015 | 1356 | 3″ | 3″ | 40 – 66 | 80 – 60 |
| SHT40/3 C | 3×11 | 380 | 50 | 2900 | 1106 | 101 | 1356 | 5″ | 4″ | 60 – 99 | 80 – 60 |
| SHT40/4 A | 1×15 | 380 | 50 | 2900 | 335 | 800 | 1511 | 2″ | 1½ | 20 – 34 | 110 – 80 |
| SHT40/4 B | 2×15 | 380 | 50 | 2900 | 675 | 1015 | 1511 | 3″ | 3″ | 40 – 68 | 110 – 80 |
| SHT40/4 C | 3×15 | 380 | 50 | 2900 | 1106 | 1015 | 1511 | 5″ | 4″ | 60 – 102 | 110 – 80 |
| SHT40/5 A | 1×18,5 | 380 | 50 | 2900 | 335 | 800 | 1610 | 2″ | 1½ | 32 – 35 | 130 – 90 |
| SHT40/5 B | 2×18,5 | 380 | 50 | 2900 | 675 | 1015 | 1610 | 3″ | 3″ | 64 – 70 | 130 – 90 |
| SHT40/5 C | 3×18,5 | 380 | 50 | 2900 | 1106 | 1015 | 1610 | 5″ | 4″ | 96 – 105 | 130 – 90 |
Definition
Booster is systems that allow water to reach comfortably and the way of operation is completely automatic according to the intended use in cases where the city mains is insufficient, in high rise buildings, in residential units with tanks for water interruption.
These pumps are manufactured at frequencies of 50 Hz and 60 Hz.
Usage Areas
These booster sets are used in residential areas, industrial facilities, apartments, villas, schools, hospitals, factories and public housing, hotels, irrigation systems, treatment plants, heating and cooling systems.
SHT50 A
SHT50 B
SHT50 C
Techical Specifications
| MOTOR | PUMP | ||||||||||
| TYPE | KW | V | Hz | rpm | W mm | L mm | H mm | MANIFOLD INPUT | MANIFOLD OUTPUT | MAX FLOW m³/h | CAPACITY mss |
| SHT50/2 A | 1×11 | 380 | 50 | 2900 | 435 | 800 | 1440 | 2½ | 2″ | 27 – 48 | 65 – 50 |
| SHT50/2 B | 2×11 | 380 | 50 | 2900 | 875 | 1515 | 1440 | 5″ | 4″ | 54 – 96 | 65 – 50 |
| SHT50/2 C | 3×11 | 380 | 50 | 2900 | 1350 | 1515 | 1440 | 6″ | 5″ | 81 – 144 | 65 – 50 |
| SHT50/2 A | 1×15 | 380 | 50 | 2900 | 435 | 800 | 1500 | 2½ | 2″ | 28 – 50 | 80 – 60 |
| SHT50/2 B | 2×15 | 380 | 50 | 2900 | 875 | 1515 | 1500 | 5″ | 4″ | 56 – 100 | 80 – 60 |
| SHT50/2 C | 3×15 | 380 | 50 | 2900 | 1350 | 1515 | 1500 | 6″ | 5″ | 84 – 150 | 80 – 60 |
| SHT50/3 A | 1×18,5 | 380 | 50 | 2900 | 435 | 800 | 1590 | 2½ | 2″ | 27 – 55 | 100 – 70 |
| SHT50/3 B | 2×18,5 | 380 | 50 | 2900 | 875 | 1015 | 1590 | 5″ | 4″ | 54 – 110 | 100 – 70 |
| SHT50/3 C | 3×18,5 | 380 | 50 | 2900 | 1350 | 1015 | 1590 | 6″ | 5″ | 81 – 165 | 100 – 70 |
| SHT50/3 A | 1×22 | 380 | 50 | 2900 | 435 | 800 | 1670 | 2½ | 2″ | 20 – 52 | 120 – 90 |
| SHT50/3 B | 2×22 | 380 | 50 | 2900 | 875 | 1015 | 1670 | 5″ | 4″ | 40 – 104 | 120 – 90 |
| SHT50/3 C | 3×22 | 380 | 50 | 2900 | 1350 | 1015 | 1670 | 6″ | 5″ | 60 – 156 | 120 – 90 |
| SHT50/4 A | 1×22 | 380 | 50 | 2900 | 435 | 800 | 1720 | 2½ | 2″ | 20 – 50 | 130 – 100 |
| SHT50/4 B | 2×22 | 380 | 50 | 2900 | 875 | 1015 | 1720 | 5″ | 4″ | 40 – 100 | 130 – 100 |
| SHT50/4 C | 3×22 | 380 | 50 | 2900 | 1350 | 1015 | 1720 | 6″ | 5″ | 60 – 150 | 130 – 100 |
| SHT50/4 A | 1×30 | 380 | 50 | 2900 | 435 | 800 | 1750 | 2½ | 2″ | 25 – 50 | 160 – 100 |
| SHT50/4 B | 2×30 | 380 | 50 | 2900 | 875 | 1015 | 1750 | 5″ | 4″ | 50 – 100 | 160 – 100 |
| SHT50/4 C | 3×30 | 380 | 50 | 290 | 1350 | 1015 | 1750 | 6″ | 5″ | 75 – 150 | 160 – 100 |
Definition
Booster systems are designed to maximize energy savings and provide constant pressure water in case of variable flow rate needs in cases where the city mains is insufficient, in high rise buildings, in residential units with tanks for water interruption.
These pumps are manufactured at frequencies of 50 Hz and 60 Hz.
Usage Areas
These booster sets are used in residential areas, industrial facilities, apartments, villas, schools, hospitals, factories and public housing, hotels, irrigation systems, treatment plants, heating and cooling systems.
SHT65 A
SHT65 B
SHT65 C
Techical Specifications
| MOTOR | PUMP | ||||||||||
| TYPE | KW | V | Hz | rpm | W mm | L mm | H mm | MANIFOLD INPUT | MANIFOLD OUTPUT | MAX FLOW m³/h | CAPACITY mss |
| SHT65/2 A | 1×30 | 380 | 50 | 2900 | 435 | 800 | 1539 | 3″ | 2½ | 45 – 75 | 75 – 60 |
| SHT65/2 B | 2×30 | 380 | 50 | 2900 | 975 | 1570 | 1539 | 6″ | 5″ | 90 – 150 | 75 – 60 |
| SHT65/2 C | 3×30 | 380 | 50 | 2900 | 1466 | 1570 | 1539 | 8″ | 6″ | 135 – 225 | 75 – 60 |
| SHT65/2 A | 1×37 | 380 | 50 | 2900 | 435 | 800 | 1559 | 3″ | 2½ | 30 – 100 | 100 – 80 |
| SHT65/2 B | 2×37 | 380 | 50 | 2900 | 975 | 1570 | 1559 | 6″ | 5″ | 60 – 200 | 100 – 80 |
| SHT65/2 C | 3×37 | 380 | 50 | 2900 | 1466 | 1570 | 1559 | 8″ | 6″ | 90 – 300 | 100 – 80 |
| SHT65/3 A | 1×45 | 380 | 50 | 2900 | 435 | 800 | 1702 | 3″ | 2½ | 50 – 80 | 130 – 120 |
| SHT65/3 B | 2×45 | 380 | 50 | 2900 | 975 | 1015 | 1702 | 6″ | 5″ | 100 – 160 | 130 – 120 |
| SHT65/3 C | 3×45 | 380 | 50 | 2900 | 1466 | 1015 | 1702 | 8″ | 6″ | 150 – 240 | 130 – 120 |
| SHT65/3 A | 1×55 | 380 | 50 | 2900 | 435 | 800 | 1702 | 3″ | 2½ | 50 – 90 | 150 – 135 |
| SHT65/3 B | 2×55 | 380 | 50 | 2900 | 975 | 1015 | 170 | 6″ | 5″ | 100 – 180 | 150 – 135 |
| SHT65/3 C | 3×55 | 380 | 50 | 2900 | 1466 | 1015 | 1702 | 8″ | 6″ | 150 – 270 | 150 – 135 |
Vertical Multistage Booster Sets
Vertical Shaft Multistage Pumps produced by turkish vertical multistage booster manufacturers are products that make it easier to use in places where there is a horizontal space problem, they are used for hydrophore purposes, The pumps are designed with more than one impeller and stage on a vertical shaft. Although the material of the pump booster’s manufactured by turkish booster producers impeller is usually noryl, they can also be manufactured as stainless and cast. Such pumps can also be used as fire pumps in small businesses. The asynchronous motor driving the pump is designed to be on the top of the pump, the pump is usually connected to the system with an easy mounting apparatus called a glen (flange) and can be easily disassembled in case of maintenance.
Booster systems from turkish booster suppliers are used in industries, hospitals, residential units, hotels, mass housing, gas stations, holiday villages, shopping malls, social facilities, fire systems for booster purposes and pressurized water needs.
Hydrophore from turkish hydrophore suppliers are electrically powered water pumps produced for the purpose of increasing the water pressure.
Regarding the selection of booster set, it should be known that , With the help of the working principle of the booster, high pressure, they deliver the water they suck from a certain water reservoir to far points. Thanks to the expansion tanks connected to the boosters, they already hold pressurized water.
Pressurized Water Boosters manufactured by turkish booster producers are used in buildings, apartments, detached villas, estates and high-rise buildings to meet the need for mains water or pressurized water from tanks in cases where the mains water pressure is not sufficient. In short, we can say that it is a water pressurization system used wherever the water pressure is insufficient. These systems, most of which work with electricity, increase the pressure of the water flowing from our taps.
Regarding the selection of the boosters , it should be known that , The difference between the booster and the pump is a detail that is often wondered. Let’s briefly explain this as follows. The booster is a whole system consisting of both the pump and the control equipment that controls the pump’s input and output.
The Booster Pump has a system consisting of protection equipment in order to ensure its long-lasting operation, so that it does not focus on a single purpose, the system in general provides control and protection.
Vertical Multistage Booster produced by turkish booster manufacturers is the name given to the pumps that are automatically activated when the water supply is insufficient. It pressurizes the water in the water tank with the pump wheels and pumps it to the far point, in short, this is the working principle. The selection of the booster pump should be completely tailored to the needs; It should be able to give the pressure to the water to go to the desired place. The booster is not only a system consisting of a water tank and a pump, but also has auxiliary elements mounted. We can count these auxiliary elements as follows; Expansion Tank, Manometer, Check Valve, Ball Valve, Pressure Switch, Control Panel and Water Level Floater.
There are some points when calculating the Gradual Booster; the number of flats and the height of the building, the location of the warehouse, the horizontal and vertical pipes in the building installation, the friction coefficient of the water in the water installation, the water supply for how many flats, the distance between the flats to be installed and the flats to be fed, etc. These details are important for choosing the right booster and provide long-term usefulness.