The difference between vertical shaft multistage boosters with digital panels and our mechanical panel boosters production is only the more elegant panel shape and all other parts are the same. These types of hydrophores, produced by Sumak pump are manufactured from very high quality materials and these types of hydrophores are under the Sumak pump warranty.
Definition
The vertical shaft multistage boosters with digital panel, smart series booster systems that provide regular and continuous water at predetermined pressures according to need, are used in places such as schools, hospitals, workplaces, public housing, hotels, etc. Vertical shaft multistage boosters with digital panel are suitable for use in hygienic environments and all surfaces that come into contact with water due to its completely stainless material. Please contact with our company for all your multiple special pump, booster pump, vertical shaft pump, multistage pump, smart booster, frequency controlled pump and booster requests. Smart series boosters are manufactured at frequencies of 50 Hz and 60 Hz.
SHTP8A SMART
SHTP8B SMART
SHTP8C SMART
Technical Specifacitons
BOOSTER SETS WITH ONE PUMPS AND DIGITAL PANEL
| Type | KW | V | Hz | rpm | Hm | W mm | L mm | H mm | MANIFOLD INPUT | MANIFOLD OUTPUT | MAX FLOW m³/h | CAPACITY mss | NUMBER OF FLATS | NUMBER OF FLOORS |
| SHTP8A-220/8 SMART | 1×1,6 | 380 | 50 | 2900 | 85 | 360 | 506 | 9+8 | 1½ | 1½ | 4 – 5 | 60 – 50 | 18 – 24 | 11 – 8 |
| SHTP8A-300/10 SMART | 1×2,2 | 380 | 50 | 2900 | 105 | 360 | 405 | 927 | 1½ | 1½ | 4 – 5 | 70 – 60 | 18 – 24 | 14 – 11 |
| SHTP8A-400/12 SMART | 1×3 | 380 | 50 | 2900 | 125 | 360 | 405 | 987 | 1½ | 1½ | 4 – 5 | 80 – 70 | 18 – 24 | 17 – 13 |
| SHTP16A-550/8 SMART | 1×4 | 380 | 50 | 2900 | 88 | 360 | 405 | 960 | 1½ | 1½ | 2,5 – 10 | 60 – 45 | 35– 48 | 11 – 7 |
| SHTP16A-550/10 SMART | 1×4 | 380 | 50 | 2900 | 112 | 360 | 405 | 1020 | 1½ | 1½ | 5 – 10 | 100 – 75 | 24 – 48 | 23 – 15 |
| SHTP16A-750/12 SMART | 1×5,5 | 380 | 50 | 2900 | 134 | 360 | 405 | 1081 | 1½ | 1½ | 6 – 10 | 120 – 85 | 28 – 48 | 28 – 19 |
| SHTP16A-750/14 SMART | 1×5,5 | 380 | 50 | 2900 | 155 | 360 | 405 | 1042 | 1½ | 1½ | 7 – 10 | 130 – 95 | 32 – 48 | 32 – 22 |
BOOSTER SETS WITH TWO PUMPS AND DIGITAL PANEL
| Type | KW | V | Hz | rpm | Hm | W mm | L mm | H mm | MANIFOLD INPUT | MANIFOLD OUTPUT | MAX FLOW m³/h | CAPACITY mss | NUMBER OF FLATS | NUMBER OF FLOORS |
| SHTP8B-220/8 SMART | 2×1,6 | 380 | 50 | 2900 | 85 | 1000 | 750 | 867 | 2″ | 2″ | 8 – 10 | 60 – 50 | 36 – 48 | 11 – 8 |
| SHTP8B-300/10 SMART | 2×2,2 | 380 | 50 | 2900 | 105 | 1000 | 750 | 927 | 2″ | 2″ | 8 – 10 | 70 – 60 | 36 – 48 | 14 – 11 |
| SHTP8B-400/12 SMART | 2×3 | 380 | 50 | 2900 | 125 | 1000 | 750 | 987 | 2″ | 2″ | 8 – 10 | 80 – 70 | 36 – 48 | 17 – 13 |
| SHTP16B-550/8 SMART | 2×4 | 380 | 50 | 2900 | 55 | 1000 | 800 | 960 | 3″ | 2½ | 5 – 20 | 60 – 45 | 70 – 96 | 11 – 7 |
| SHTP16B-550/10 SMART | 2×4 | 380 | 50 | 2900 | 112 | 1000 | 800 | 1020 | 3″ | 2½ | 10 – 20 | 100 – 75 | 48 – 96 | 23 – 15 |
| SHTP16B-750/12 SMART | 2×5,5 | 380 | 50 | 2900 | 134 | 1000 | 800 | 1081 | 3″ | 2½ | 12 – 20 | 120 – 85 | 56 – 96 | 28 – 19 |
| SHTP16B-750/14 SMART | 2×5,5 | 380 | 50 | 2900 | 155 | 1000 | 800 | 1042 | 3″ | 2½ | 14 – 20 | 130 – 95 | 64 – 96 | 32 – 22 |
| BOOSTER SETS WITH THREE PUMPS AND DIGITAL PANEL | ||||||||||||||
| Type | KW | V | Hz | rpm | Hm | W mm | L mm | H mm | MANIFOLD INPUT | MANIFOLD OUTPUT | MAX FLOW m³/h | CAPACITY mss | NUMBER OF FLATS | NUMBER OF FLOORS |
| SHTP8C-220/8 SMART | 3×1,6 | 380 | 50 | 2900 | 85 | 1300 | 750 | 867 | 2″ | 2″ | 12 – 15 | 60 – 50 | 54 – 72 | 11 – 8 |
| SHTP8C-300/10 SMART | 3×2,2 | 380 | 50 | 2900 | 105 | 1300 | 750 | 927 | 2″ | 2″ | 12 – 15 | 70 – 60 | 54 – 72 | 14 – 11 |
| SHTP8C-400/12 SMART | 3×3 | 380 | 50 | 2900 | 125 | 1300 | 750 | 987 | 2″ | 2″ | 12 – 15 | 80 – 70 | 54 – 72 | 17 – 13 |
| SHTP16C-550/8 SMART | 3×4 | 380 | 50 | 2900 | 88 | 1300 | 800 | 960 | 3″ | 2½ | 7,5 – 30 | 60 – 45 | 105 – 144 | 11 – 7 |
| SHTP16C-550/10 SMART | 3×4 | 380 | 50 | 2900 | 112 | 1300 | 800 | 1020 | 3″ | 2½ | 15 – 30 | 100 – 75 | 72 – 144 | 23 – 15 |
| SHTP16C-750/12 SMART | 3×5,5 | 380 | 50 | 2900 | 134 | 1300 | 800 | 1081 | 3″ | 2½ | 18 – 30 | 120 – 85 | 85 – 144 | 28 – 19 |
| SHTP16C-750/14 SMART | 3×5,5 | 380 | 50 | 2900 | 155 | 1300 | 800 | 1042 | 3″ | 2½ | 21 – 30 | 130 – 95 | 96 – 144 | 32 – 22 |
Definition
The smart series booster systems that provide regular and continuous water at predetermined pressures according to need, are used in places such as schools, hospitals, workplaces, public housing, hotels, etc. These boosters are suitable for use in all environments due to its product is completely stainless body on all surfaces that come into contact with water, except the pump input and output. Please contact with our company for all your multiple special pump, booster pump, vertical shaft pump, multistage pump, smart booster, frequency controlled pump and booster requests. Smart series boosters are manufactured at frequencies of 50 Hz and 60 Hz.
SHTPD8A SMART
SHTPD8B SMART
SHTPD8C SMART
Technical Specifacitons
| BOOSTER SETS WITH ONE PUMPS AND DIGITAL PANEL | ||||||||||||||
| Type | KW | V | Hz | d/d | Hm | W mm | L mm | H mm | MANIFOLD INPUT | MANIFOLD OUTPUT | MAX FLOW m³/h | CAPACITY mss | NUMBER OF FLATS | NUMBER OF FLOORS |
| SHTPD8A-220/8 SMART | 1×1,6 | 380 | 50 | 2900 | 85 | 360 | 506 | 9+8 | 1½ | 1½ | 4 – 5 | 60 – 50 | 18 – 24 | 11 – 8 |
| SHTPD8A-300/10 SMART | 1×2,2 | 380 | 50 | 2900 | 105 | 360 | 405 | 927 | 1½ | 1½ | 4 – 5 | 70 – 60 | 18 – 24 | 14 – 11 |
| SHTPD8A-400/12 SMART | 1×3 | 380 | 50 | 2900 | 125 | 360 | 405 | 987 | 1½ | 1½ | 4 – 5 | 80 – 70 | 18 – 24 | 17 – 13 |
| SHTPD16A-550/8 SMART | 1×4 | 380 | 50 | 2900 | 88 | 360 | 405 | 960 | 1½ | 1½ | 2,5 – 10 | 60 – 45 | 35 – 48 | 11 – 7 |
| SHTPD16A-550/10 SMART | 1×4 | 380 | 50 | 2900 | 112 | 360 | 405 | 1020 | 1½ | 1½ | 5 – 10 | 100 – 75 | 24 – 48 | 23 – 15 |
| SHTPD16A-750/12 SMART | 1×5,5 | 380 | 50 | 2900 | 134 | 360 | 405 | 1081 | 1½ | 1½ | 6 – 10 | 120 – 85 | 28 – 48 | 28 – 19 |
| SHTPD16A-750/14 SMART | 1×5,5 | 380 | 50 | 2900 | 155 | 360 | 405 | 1042 | 1½ | 1½ | 7 – 10 | 130 – 95 | 32 – 48 | 32 – 22 |
| BOOSTER SETS WITH TWO PUMPS AND DIGITAL PANEL | ||||||||||||||
| Type | KW | V | Hz | rpm | Hm | W mm | L mm | H mm | MANIFOLD INPUT | MANIFOLD OUTPUT | MAX FLOW m³/h | CAPACITY mss | NUMBER OF FLATS | NUMBER OF FLOORS |
| SHTPD8B-220/8 SMART | 2×1,6 | 380 | 50 | 2900 | 85 | 1000 | 750 | 867 | 2″ | 2″ | 8 – 10 | 60 – 50 | 36 – 48 | 11 – 8 |
| SHTPD8B-300/10 SMART | 2×2,2 | 380 | 50 | 2900 | 105 | 1000 | 750 | 927 | 2″ | 2″ | 8 – 10 | 70 – 60 | 36 – 48 | 14 – 11 |
| SHTPD8B-400/12 SMART | 2×3 | 380 | 50 | 2900 | 125 | 1000 | 750 | 987 | 2″ | 2″ | 8 – 10 | 80 – 70 | 36 – 48 | 17 – 13 |
| SHTP16B-550/8 SMART | 2×4 | 380 | 50 | 2900 | 55 | 1000 | 800 | 960 | 3″ | 2½ | 5 – 20 | 60 – 45 | 70 – 96 | 11 – 7 |
| SHTPD16B-550/10 SMART | 2×4 | 380 | 50 | 2900 | 112 | 1000 | 800 | 1020 | 3″ | 2½ | 10 – 20 | 100 – 75 | 48 – 96 | 23 – 15 |
| SHTPD16B-750/12 SMART | 2×5,5 | 380 | 50 | 2900 | 134 | 1000 | 800 | 1081 | 3″ | 2½ | 12 – 20 | 120 – 85 | 56 – 96 | 28 – 19 |
| SHTPD16B-750/14 SMART | 2×5,5 | 380 | 50 | 2900 | 155 | 1000 | 800 | 1042 | 3″ | 2½ | 14 – 20 | 130 – 95 | 64 – 96 | 32 – 22 |
BOOSTER SETS WITH THREE PUMPS AND DIGITAL PANEL
| Type | KW | V | Hz | rpm | Hm | W mm | L mm | H mm | MANIFOLD INPUT | MANIFOLD OUTPUT | MAX FLOW m³/h | CAPACITY mss | NUMBER OF FLATS | NUMBER OF FLOORS |
| SHTPD8C-220/8 SMART | 3×1,6 | 380 | 50 | 2900 | 85 | 1300 | 750 | 867 | 2″ | 2″ | 12 – 15 | 60 – 50 | 54 – 72 | 11 – 8 |
| SHTPD8C-300/10 SMART | 3×2,2 | 380 | 50 | 2900 | 105 | 1300 | 750 | 927 | 2″ | 2″ | 12 – 15 | 70 – 60 | 54 – 72 | 14 – 11 |
| SHTPD8C-400/12 SMART | 3×3 | 380 | 50 | 2900 | 125 | 1300 | 750 | 987 | 2″ | 2″ | 12 – 15 | 80 – 70 | 54 – 72 | 17 – 13 |
| SHTPD16C-550/8 SMART | 3×4 | 380 | 50 | 2900 | 88 | 1300 | 800 | 960 | 3″ | 2½ | 7,5 – 30 | 60 – 45 | 105 – 144 | 11 – 7 |
| SHTPD16C-550/10 SMART | 3×4 | 380 | 50 | 2900 | 112 | 1300 | 800 | 1020 | 3″ | 2½ | 15 – 30 | 100 – 75 | 72 – 144 | 23 – 15 |
| SHTPD16C-750/12 SMART | 3×5,5 | 380 | 50 | 2900 | 134 | 1300 | 800 | 1081 | 3″ | 2½ | 18 – 30 | 120 – 85 | 85 – 144 | 28 – 19 |
| SHTPD16C-750/14 SMART | 3×5,5 | 380 | 50 | 2900 | 155 | 1300 | 800 | 1042 | 3″ | 2½ | 21 – 30 | 130 – 95 | 96 – 144 | 32 – 22 |
Definition
The smart series booster systems that provide regular and continuous water at predetermined pressures according to need, are used in places such as schools, hospitals, workplaces, public housing, hotels, etc. Please contact with our company for all your multiple special pump, booster pump, vertical shaft pump, multistage pump, smart booster, frequency controlled pump and booster requests. Smart series boosters are manufactured at frequencies of 50 Hz and 60 Hz.
SHT6A SMART
SHT6B SMART
SHT6C SMART
Technical Specifacitons
| BOOSTER SETS WITH ONE PUMPS AND DIGITAL PANEL | |||||||||||||||
| Type | KW | V Mono | V Tri | Hz | rpm | Hm | W mm | L mm | H mm | MANIFOLD INPUT | MANIFOLD OUTPUT | MAX FLOW m³/h | CAPACITY mss | NUMBER OF FLATS | NUMBER OF FLOORS |
| SHT6A-100/6 SMART | 1×0,75 | 220 | 380 | 50 | 2900 | 55 | 340 | 290 | 570 | 1¼ | 1″ | 2,5 – 4,0 | 42 – 25 | 15-12 | 3 – 6 |
| SHT6A-150/8 SMART | 1×1,1 | 220 | 380 | 50 | 2900 | 72 | 340 | 290 | 570 | 1¼ | 1″ | 2,5 – 4,2 | 50 – 30 | 12 – 20 | 9 – 4 |
| SHT6A-180/10 SMART | 1×1,35 | – | 380 | 50 | 2900 | 92 | 340 | 290 | 610 | 1¼ | 1″ | 2,6 – 3,4 | 60 – 50 | 12 – 16 | 12 – 8 |
| SHT8A-220/6 SMART | 1×1,6 | 220 | 380 | 50 | 2900 | 88 | 350 | 290 | 610 | 1¼ | 1¼ | 3,5 – 6 | 70 – 40 | 15 – 28 | 14 – 6 |
| SHT8A-300/8 SMART | 1×2,2 | – | 380 | 50 | 2900 | 110 | 350 | 290 | 610 | 1¼ | 1¼ | 4 – 5,5 | 80 – 60 | 18 – 26 | 17 – 10 |
| SHT8A-400/10 SMART | 1×3 | – | 380 | 50 | 2900 | 135 | 350 | 290 | 640 | 1¼ | 1¼ | 4 – 5 | 90 – 80 | 21 – 24 | 20 – 17 |
BOOSTER SETS WITH TWO PUMPS AND DIGITAL PANEL
| Type | KW | V Mono | V Tri | Hz | rpm | Hm | W mm | L mm | H mm | MANIFOLD INPUT | MANIFOLD OUTPUT | MAX FLOW m³/h | CAPACITY mss | NUMBER OF FLATS | NUMBER OF FLOORS |
| SHT6B-100/6 SMART | 2×0,75 | 220 | 380 | 50 | 2900 | 55 | 940 | 465 | 820 | 2″ | 2″ | 5,0 – 8,0 | 42 – 25 | 30-24 | 3 – 6 |
| SHT6B-150/8 SMART | 2×1,1 | 220 | 380 | 50 | 2900 | 72 | 940 | 465 | 820 | 2″ | 2″ | 5,0 – 8,4 | 50 – 30 | 24 – 40 | 9 – 4 |
| SHT6B-180/10 SMART | 2×1,35 | – | 380 | 50 | 2900 | 92 | 940 | 465 | 820 | 2″ | 2″ | 5,2 – 6,8 | 60 – 50 | 24 – 32 | 12 – 8 |
| SHT8B-220/6 SMART | 2×1,6 | 220 | 380 | 50 | 2900 | 88 | 940 | 465 | 820 | 2″ | 2″ | 7 – 12 | 70 – 40 | 30 – 56 | 14 – 6 |
| SHT8B-300/8 SMART | 2×2,2 | – | 380 | 50 | 2900 | 110 | 940 | 465 | 820 | 2″ | 2″ | 8 – 11 | 80 – 60 | 36 – 52 | 17 – 10 |
| SHT8B-400/10 SMART | 2×3 | – | 380 | 50 | 2900 | 135 | 940 | 465 | 820 | 2″ | 2″ | 8 – 10 | 90 – 80 | 42 – 48 | 20 – 17 |
BOOSTER SETS WITH THREE PUMPS AND DIGITAL PANEL
| Type | KW | V Mono | V Tri | Hz | rpm | Hm | W mm | L mm | H mm | MANIFOLD INPUT | MANIFOLD OUTPUT | MAX FLOW m³/h | CAPACITY mss | NUMBER OF FLATS | NUMBER OF FLOORS |
| SHT6C-100/6 SMART | 3×0.75 | – | 380 | 50 | 2900 | 55 | 1190 | 465 | 820 | 2″ | 2″ | 12 – 7.5 | 2.5 – 4.2 | 30-24 | 3 – 6 |
| SHT6C-150/8 SMART | 3×1.1 | – | 380 | 50 | 2900 | 72 | 1190 | 465 | 820 | 2″ | 2″ | 12.6 – 7.5 | 3 – 5 | 24 – 40 | 9 – 4 |
| SHT6C-180/10 SMART | 3×1.35 | – | 380 | 50 | 2900 | 92 | 1190 | 465 | 585 | 2″ | 2″ | 10.2 – 7.6 | 5 – 6 | 24 – 32 | 12 – 8 |
| SHT8C-220/6 SMART | 3×1.6 | – | 380 | 50 | 2900 | 88 | 1190 | 550 | 820 | 3″ | 2″ | 18 – 9 | 4 – 7 | 30 – 56 | 14 – 6 |
| SHT8C-300/8 SMART | 3×2.2 | – | 380 | 50 | 2900 | 110 | 1190 | 550 | 820 | 3″ | 2″ | 16 – 12 | 6 – 8 | 36 – 52 | 17 – 10 |
| SHT8C-400/10 SMART | 3×3 | – | 380 | 50 | 2900 | 135 | 1190 | 550 | 820 | 3″ | 2″ | 15 – 13.5 | 8 – 9 | 42 – 48 | 20 – 17 |
Definition
The smart series booster systems that provide regular and continuous water at predetermined pressures according to need, are used in places such as schools, hospitals, workplaces, public housing, hotels, etc. Please contact with our company for all your multiple special pump, booster pump, vertical shaft pump, multistage pump, smart booster, frequency controlled pump and booster requests. Smart series boosters are manufactured at frequencies of 50 Hz and 60 Hz.
SHT12A SMART
SHT12B SMART
SHT12C SMART
Technical Specifacitons
BOOSTER SETS WITH ONE PUMPS AND DIGITAL PANEL
| Type | KW | V Mono | V Tri | Hz | rpm | Hm | W mm | L mm | H mm | MANIFOLD INPUT | MANIFOLD OUTPUT | MAX FLOW m³/h | CAPACITY mss | NUMBER OF FLATS | NUMBER OF FLOORS |
| SHT12A-220/4 SMART | 1×1,6 | 220 | 380 | 50 | 2900 | 60 | 350 | 290 | 580 | 1¼ | 1¼ | 5 – 9 | 50 – 30 | 28-48 | 9 – 4 |
| SHT12A-300/6 SMART | 1×2,2 | – | 380 | 50 | 2900 | 82 | 350 | 290 | 580 | 1¼ | 1¼ | 4 – 7,5 | 70 – 50 | 19 – 35 | 14 – 9 |
| SHT12A-400/7 SMART | 1×3 | – | 380 | 50 | 2900 | 96 | 350 | 290 | 585 | 1¼ | 1¼ | 3,5 – 7 | 80 – 70 | 17 – 33 | 17 – 14 |
| SHT16A-550/4 SMART | 1×4 | – | 380 | 50 | 2900 | 75 | 370 | 330 | 620 | 1½ | 1¼ | 4 – 16 | 70 – 40 | 19 – 76 | 13-3 |
| SHT16A-550/5 SMART | 1×4 | – | 380 | 50 | 2900 | 90 | 370 | 330 | 660 | 1½ | 1¼ | 8 – 11 | 90 – 60 | 38 – 52 | 14 – 11 |
| SHT16A-750/6 SMART | 1×5,5 | – | 380 | 50 | 2900 | 110 | 370 | 330 | 700 | 1½ | 1¼ | 7 – 14 | 100 – 80 | 32 – 64 | 20-10 |
| SHT16A-750/7 SMART | 1×5,5 | – | 380 | 50 | 2900 | 125 | 370 | 330 | 740 | 1½ | 1¼ | 6 – 13 | 110 – 90 | 28 – 60 | 25 – 15 |
| SHT16A-850/8 SMART | 1×6,3 | – | 380 | 50 | 2900 | 142 | 370 | 330 | 740 | 1½ | 1¼ | 6 – 13 | 120 – 100 | 28 – 60 | 28 – 23 |
BOOSTER SETS WITH TWO PUMPS AND DIGITAL PANEL
| Type | KW | V Mono | V Tri | Hz | rpm | Hm | W mm | L mm | H mm | MANIFOLD INPUT | MANIFOLD OUTPUT | MAX FLOW m³/h | CAPACITY mss | NUMBER OF FLATS | NUMBER OF FLOORS |
| SHT12B-220/4 SMART | 2×1,6 | 220 | 380 | 50 | 2900 | 60 | 940 | 465 | 820 | 2″ | 2″ | 10 – 18 | 50 – 30 | 56-96 | 9 – 4 |
| SHT12B-300/6 SMART | 2×2,2 | – | 380 | 50 | 2900 | 82 | 940 | 465 | 820 | 2″ | 2″ | 8 – 15 | 70 – 50 | 38 – 80 | 14 – 9 |
| SHT12B-400/7 SMART | 2×3 | – | 380 | 50 | 2900 | 96 | 940 | 465 | 585 | 2″ | 2″ | 7 – 14 | 80 – 70 | 32 – 66 | 17 – 14 |
| SHT16B-550/4 SMART | 2×4 | – | 380 | 50 | 2900 | 75 | 940 | 550 | 820 | 3″ | 2½ | 8 – 32 | 70 – 40 | 38 – 150 | 13-3 |
| SHT16B-550/5 SMART | 2×4 | – | 380 | 50 | 2900 | 90 | 940 | 550 | 820 | 3″ | 2½ | 16 – 22 | 90 – 60 | 76 – 104 | 14 – 11 |
| SHT16B-750/6 SMART | 2×5,5 | – | 380 | 50 | 2900 | 110 | 940 | 550 | 820 | 3″ | 2½ | 14 – 28 | 100 – 80 | 64 – 128 | 20-10 |
| SHT16B-750/7 SMART | 2×5,5 | – | 380 | 50 | 2900 | 125 | 940 | 550 | 820 | 3″ | 2½ | 12 – 26 | 110 – 90 | 56 – 120 | 25 – 15 |
| SHT16B-850/8 SMART | 2×6,3 | – | 380 | 50 | 2900 | 142 | 940 | 550 | 820 | 3″ | 2½ | 12 – 26 | 120 – 100 | 56 – 120 | 28 – 18 |
| BOOSTER SETS WITH THREE PUMPS AND DIGITAL PANEL | |||||||||||||||
| Type | KW | V Mono | V Tri | Hz | rpm | Hm | W mm | L mm | H mm | MANIFOLD INPUT | MANIFOLD OUTPUT | MAX FLOW m³/h | CAPACITY mss | NUMBER OF FLATS | NUMBER OF FLOORS |
| SHT12C-220/4 SMART | 3×1,6 | 220 | 380 | 50 | 2900 | 60 | 1190 | 465 | 820 | 2″ | 2″ | 15 – 27 | 50 – 30 | 84-144 | 9 – 4 |
| SHT12C-300/6 SMART | 3×2,2 | – | 380 | 50 | 2900 | 82 | 1190 | 465 | 820 | 2″ | 2″ | 12 – 22,5 | 70 – 50 | 56 – 106 | 14 – 9 |
| SHT12C-400/7 SMART | 3×3 | – | 380 | 50 | 2900 | 96 | 1190 | 465 | 585 | 2″ | 2″ | 10 – 21 | 80 – 70 | 45 – 100 | 17 – 14 |
| SHT16C-550/4 SMART | 3×4 | – | 380 | 50 | 2900 | 75 | 1190 | 550 | 820 | 3″ | 2½ | 12 – 48 | 70 – 40 | 57 – 225 | 13-3 |
| SHT16C-550/5 SMART | 3×4 | – | 380 | 50 | 2900 | 90 | 1190 | 550 | 820 | 3″ | 2½ | 24 – 33 | 90 – 60 | 112 – 152 | 14-11 |
| SHT16C-750/6 SMART | 3×5,5 | – | 380 | 50 | 2900 | 110 | 1190 | 550 | 820 | 3″ | 2½ | 21 – 42 | 100 – 80 | 100 – 200 | 20-10 |
| SHT16C-750/7 SMART | 3×5,5 | – | 380 | 50 | 2900 | 125 | 1190 | 550 | 820 | 3″ | 2½ | 18 – 39 | 110 – 90 | 81 – 180 | 25 – 15 |
| SHT16C-850/8 SMART | 3×6,3 | – | 380 | 50 | 2900 | 142 | 1190 | 550 | 820 | 3″ | 2½ | 18 – 39 | 120 – 100 | 81 – 184 | 28 – 18 |
Vertical Shaft Multistage Boosters with Digital Panel
Booster Water Pumps are electrically operated water pumps produced by turkish water booster set manufacturers for the purpose of increasing the water pressure system. With the help of high pressure, the boosters deliver the water they absorb from a certain water tank to distant points. due to the expansion tanks connected to the boosters, they already hold pressurized water.
Hydrophores with Electric Panel manufactured by turkish hydrophores producers are used in buildings, apartments, detached villas, estates and high-rise buildings to meet the need for mains water or pressurized water from tanks in cases where the mains water pressure is not sufficient. In short, we can say that it is a water pressurization system used wherever the water pressure is insufficient. These systems produced by turkish booster suppliers , most of which work with electricity, increase the pressure of the water flowing from our taps.
Booster is the name given to the pumps that are automatically activated when the water booster is insufficient. It pressurizes the water in the water tank with air and pumps it to the far point, in short, this is the working principle. The selection of the booster pump should be completely tailored to the needs; It should be able to give the pressure to the water to go to the desired place. The booster manufactured by turkish booster producers is not only a system consisting of a water tank and a pump, but also has auxiliary elements mounted. We can count these auxiliary elements as follows; Expansion Tank, Manometer, Check Valve, Ball Valve, Pressure Switch, Control Panel and Water Level Floater.
Electric Control Panel; It is a panel that provides electrical protection for the pump, which contains elements such as contactor, thermal, phase protection relay, to provide longer service life.
Unlike mechanical panels, water boosters with digital panels produced by turkish hydrophores suppliers can control the pump they are connected to, with an electronic card and integrated software. Along with the developing technology, pump automation has also advanced a lot. We can easily control the situations that are not possible to control in mechanical pumps in electronic panels. For example, we can set the maximum number of starts of a pump per hour, we can prevent the pump from working without water using the current drawn by the pump without using any level floater, we can make the pressure digitally plus or minus, and many more similar features are offered to the users in the booster sets with digital panels. Software boards can be very feature-rich compared to other boards. With the software, equal aging, that is, rotation, can be made between the pumps, the operating times of the pumps can be recorded, and retrospective analyzes can be made by recording the errors that the pumps have made.
Regarding the booster set installation , Water Level Floater ; This part, also known as the float, controls the water condition in the tank where the pump sucks and prevents the pump from running without water.
If we explain the working principle of the booster; pressure switch sends the necessary signal to the control panel for the pump to operate for the desired pressure in the installation. If the necessary conditions for the operation of the pump are met, the control panel starts the pump by starting it. When there is no use left in the building, when the pressure switch in the installation reaches the desired upper pressure level, the signal to the control panel to stop the booster is cut off and the pump goes into standby mode. When the water usage starts in the building, the booster pump is activated again when the pressure value in the installation reaches the lower value of the pressure switch.