Vertical Shaft Multi Stage Booster Sets

SMJH 85

SMINOX H 150-4

SYMH 12

Definition

These boosters are systems that enable water to reach comfortably in cases where the city mains water is insufficient, in high rise buildings, in residential units with tanks for water interruption and they operate completely automatically according to their intended use.
These pumps are manufactured at frequencies of 50 Hz and 60 Hz.

Usage Areas

These pumps are used in residential areas, apartments, villas, schools, hospitals, factories and public housing, hotels and garden irrigation.

Techical Specifications

PACKAGE BOOSTERS WITH JET PUMP
TYPEKWHPV
Mono
V
Tri
WORKING PRESSUREm³/h
Max
TANK
VOLUME
W
mm
L
mm
H
mm
NUMBER OF FLATSNUMBER OF FLOORS
SMJH 85
(FLOATER)
0,650,852203802 – 43,52435044059044
SMJKH 100 (FLOATER)0,7512202 – 4,53,52435044059055
SMJH 150
(FLOATER)
1,11,52203803 – 54,550350630720105
SMJH 220
(FLOATER)
1,62,22203804 – 66100475845810168
PACKAGE BOOSTERS WITH STAINLESS CENTRIFUGAL PUMP
TYPEKWHPV
Mono
V
Tri
WORKING PRESSUREm³/h
Max
TANK
VOLUME
W
mm
L
mm
H
mm
NUMBER OF FLATSNUMBER OF FLOORS
SMINOX H 150/41,11,52203803 – 55,850350650720125
SMINOX H 150/4 T
1,11,52203803 – 55,850350650720125
PACKAGE BOOSTERS WITH HORIZONTAL MULTISTAGE PUMP
TYPEKWHPV
Mono
V
Tri
WORKING PRESSUREm³/h
Max
TANK
VOLUME
W
mm
L
mm
H
mm
NUMBER OF FLATSNUMBER OF FLOORS
SYMH6-100/6
SYMTH6-100/6
(FLOATER+CONTROL PANEL)

0.75

220 

380 

 3-5

 6

100 

 505

795 

840 

12-16 

6-

SYMH6-150/8
SYMTH6-150/8
(FLOATER+CONTROL PANEL)

 1.1

1.5 

 220

380 

4-6 

100 

505 

880 

840 

12-18 

9-4 

SYMH8-220/6
SYMTH8-220/6
(FLOATER+CONTROL PANEL)

1,6

2,2

220

380

5 – 7

8

100

505

795

840

16-28

14-6

SYMTH8-300/8
(FLOATER+CONTROL PANEL)

2,2

33808 – 10810050580084020-2817-10
SYMH12-220/4
SYMTH12-220/4
(FLOATER+CONTROL PANEL)

1,6

2,2

220

380

3 – 5

12

100

505

785

840

24-48

9-4

SYMTH12-300/6
(FLOATER+CONTROL PANEL)
2,233805 – 71210050579084024-3814-9

Definition

These boosters are systems that enable water to reach comfortably in cases where the city mains water is insufficient, in high rise buildings, in residential units with tanks for water interruption and they operate completely automatically according to their intended use.
This type of boosters are self priming (4 meters) systems.
It is suitable for use in hygienic environments because its all surfaces in contact with water are completely stainless steel.
These pumps are manufactured at frequencies of 50 Hz and 60 Hz.

Usage Areas

These boosters are used in residential areas, industrial facilities, apartments, villas, schools, hospitals, factories and public housing, hotels, irrigation systems, treatment plants, heating and cooling systems.

SMINOX12A220/2

SMINOX12B220/2

SMINOX12C220/2

Techical Specifications

MOTOR PUMP
TypeKWV
Mono
V
​Tri
HzrpmHmW
mm
L
mm
H
mm
MANIFOLD INPUTMANIFOLD OUTPUTMAX FLOW
m³/h
CAPACITY
mss
NUMBER OF FLATSNUMBER OF FLOORS
SMINOX12A220/21×1,6220380502900524805204959 – 327 – 4540 – 142 – 7
SMINOX12B220/22×1,6220380502900528505207002″18 – 627 – 4580 – 282 – 7
SMINOX12C220/23×1,62203805029005211555207002″27 – 927 – 45120 – 422 – 7
SMINOX12A300/3T1×2,2380502900724805204959 – 335 – 6040 – 144 – 11
SMINOX12B300/3T2×2,2380502900728505207002″18 – 635 – 6080 – 284 – 11
SMINOX12C300/3T3×2,23805029007211555207002″27 – 935 – 60120 – 424 – 11

Definition

These boosters are systems that enable water to reach comfortably in cases where the city mains water is insufficient, in high rise buildings, in residential units with tanks for water interruption and they operate completely automatically according to their intended use.
This type of boosters are self priming (4 meters) systems.
These pumps are manufactured at frequencies of 50 Hz and 60 Hz.

Usage Areas

These boosters are used in residential areas, industrial facilities, apartments, villas, schools, hospitals, factories and public housing, hotels, irrigation systems, treatment plants, heating and cooling systems.

SMKT A 750

SMKT B 750

SMKT C 750

Technical Specifications

MOTOR PUMP
TypeKWVHzrpmHmW
mm
L
mm
H
mm
MANIFOLD INPUTMANIFOLD OUTPUTMAX FLOW
m³/h
CAPACITY
bar
NUMBER OF FLATSNUMBER OF FLOORS
SMKTA5501×43805029007850055060015-104.5-745 – 7014 – 7
SMKTB5502×438050290078950790700330-204.5-790 – 14014 – 7
SMKTC5503×43805029007813107907003″45-304.5-7135 – 21014 – 7
SMKTA7501×5,53805029008750055060015-105.5-845 – 7017 – 10
SMKTB7502×5,5380502900879507907003 30-205.5-890 – 14017 – 10
SMKTC7503×5,5380502900871310790700345-305.5-8135 – 21017 – 10
SMKTA550/21×4380502900585005506002225-103-5.545 – 11510 – 3
SMKTB550/22×4380502900589508507002350-203-5.590 – 23010 – 3
SMKTC550/23×43805029005813108507002375-303-5.5135 – 34510 – 3
SMKTA750/21×5,53805029006850055060022″25-104-645 – 11511 – 6
SMKTB750/22×5,53805029006895085070023″50-204-690 – 23011 – 6
SMKTC750/23×5,538050290068131085070023″75-304-6135 – 34511 – 6

Definition

These boosters are systems that enable water to reach comfortably in cases where the city mains water is insufficient, in high rise buildings, in residential units with for water interruption and they operate completely automatically according to their intended use.
These pumps are manufactured at frequencies of 50 Hz and 60 Hz.

Usage Areas

These boosters are used in residential areas, industrial facilities, apartments, villas, schools, hospitals, factories and public housing, hotels, irrigation systems, treatment plants, heating and cooling systems.

SHTP8 A

SHTP8 B

SHTP8 C

Techical Specifications

 

MOTORPUMP
TYPEKWVHzrpmW
mm
L
mm
H
mm
MANIFOLD INPUTMANIFOLD OUTPUTMAX FLOW
m³/h
CAPACITY 
mss
NUMBER OF FLATSNUMBER OF FLOORS
SHTP8A-220/81×1,63805029003604058675-45 – 618 – 2411 – 8
SHTP8B-220/82×1,638050290010007508672″2″10 – 85 – 636 – 4811 – 8
SHTP8C-220/83×1,638050290013007508672″2″15 – 125 -654 – 7211 – 8
SHTP8A-300/101×2,23805029003604059275 – 46 – 718 – 2414 – 11
SHTP8B-300/102×2,238050290010007509272″2″10 – 86 – 736 – 4814 – 11
SHTP8C-300/103×2,238050290013007509272″2″15 – 126 – 754 – 7214 – 11
SHTP8A-400/121×33805029003604059875 – 46.5-818 – 2417 – 13
SHTP8B-400/122×338050290010007509872″2″10 – 86.5-836 – 4817 – 13
SHTP8C-400/123×338050290013007509872″2″15 – 126.5-854 – 7217 – 13
SHTP16A-550/81×43805029003604059609 – 55.5 – 7.535-4811 – 7
SHTP16B-550/82×438050290010008009603″18 – 105.5 – 7.570-9611 – 7
SHTP16C-550/83×438050290013008009603″27 – 155.5 – 7.5105 – 14411 – 7
SHTP16A-550/101×4380502900360405102010 – 57.5 – 1024 – 4823 – 15
SHTP16B-550/102×4380502900100080010203″20 – 107.5 – 1048 – 9623 – 15
SHTP16C-550/103×4380502900130080010203″30 – 157.5 – 1072 – 14423 – 15
SHTP16A-750/121×5,5380502900360405108110 – 68.5 – 1228 – 4828 – 19
SHTP16B-750/122×5,5380502900100080010813″20 – 128.5 – 1256 – 9628 – 19
SHTP16C-750/123×5,5380502900130080010813″30 – 188.5 – 1285 – 14428 – 19
SHTP16A-750/141×5,5380502900360405104210 -79.5 – 1332 – 4832 – 22
SHTP16B-750/142×5,5380502900100080010423″20 – 149.5 – 1364 – 9632 – 22
SHTP16C 750/143×5.5380502900130080010423″30-219.5 – 1396-4432-22

Definition

These boosters are systems that enable water to reach comfortably in cases where the city mains water is insufficient, in high rise buildings, in residential units with tanks for water interruption and they operate completely automatically according to their intended use.
These pumps are manufactured at frequencies of 50 Hz and 60 Hz.

Usage Areas

These boosters are used in residential areas, industrial facilities, apartments, villas, schools, hospitals, factories and public housing, hotels, irrigation systems, treatment plants, heating and cooling systems.

SHTPD8 A

SHTPD8 B

SHTPD8 C

Techical Specifications

MOTORPUMP
TYPEKWVHzrpmW
mm
L
mm
H
mm
MANIFOLD INPUTMANIFOLD OUTPUTMAX FLOW
m³/h

CAPACITY mss

NUMBER OF FLATSNUMBER OF FLOORS
SHTPD8A-220/81×1,63805029003605069+85-45-618 – 2411 – 8
SHTPD8B-220/82×1,638050290010007508672″2″10-85-636 – 4811 – 8
SHTPD8C-220/83×1,638050290013007508672″2″12 – 155-654 – 7211 – 8
SHTPD8A-300/101×2,23805029003604059275-46-718 – 2414 – 11
SHTPD8B-300/102×2,238050290010007509272″2″10-86-736 – 4814 – 11
SHTPD8C-300/103×2,238050290013007509272″2″15-126-754 – 7214 – 11
SHTPD8A-400/121×33805029003604059875-46.5-818 – 2417 – 13
SHTPD8B-400/122×338050290010007509872″2″10-86.5-836 – 4817 – 13
SHTPD8C-400/123×338050290013007509872″2″15-126.5-854 – 7217 – 13
SHTPD16A-550/81×438050290036040596010-2.54.5-635– 4811 – 7
SHTPD16B-550/82×438050290010008009603″20-54.5-670– 9611 – 7
SHTPD16C-550/83×438050290013008009603″30-7.54.5-6105– 14411 – 7
SHTPD16A-550/101×4380502900360405102010-57.5-1024 – 4823 – 15
SHTPD16B-550/102×4380502900100080010203″20-107.5-1048 – 9623 – 15
SHTPD16C-550/103×4380502900130080010203″30-157.5-1072 – 14423 – 15
SHTPD16A-750/121×5,5380502900360405108110-68.5-1228 – 4828 – 19
SHTPD16B-750/122×5,5380502900100080010813″20-128.5-1256 – 9628 – 19
SHTPD16C-750/123×5,5380502900130080010813″30-188.5-1285 – 14428 – 19
SHTPD16A-750/141×5,5380502900360405104210-79.5-1332 – 4832 – 22
SHTPD16B-750/142×5,5380502900100080010423″20-149.5-1364 – 9632 – 22
SHTPD16C-750/143×5,5380502900130080010423″30-219.5-1396 – 14432 – 22

Definition

Booster is systems that allow water to reach comfortably and the way of operation is completely automatic according to the intended use in cases where the city mains is insufficient, in high rise buildings, in residential units with tanks for water interruption.
These pumps are manufactured at frequencies of 50 Hz and 60 Hz.

Usage Areas

These booster sets are used in residential areas, industrial facilities, apartments, villas, schools, hospitals, factories and public housing, hotels, irrigation systems, treatment plants, heating and cooling systems.

SHT6 A

SHT6 B

SHT6 C

Techical Specifications

MOTORPUMP
TYPEKWV
Mono
V
Tri
HzrpmW
mm
L
mm
H
mm
MANIFOLD INPUTMANIFOLD OUTPUTMAX FLOW
m³/h
CAPACITY
mss
NUMBER OF FLATSNUMBER OF FLOORS
SHT6A-100/61×0,752203805029003402905701″2,5 – 4,042 – 2512 – 166-3
SHT6B-100/62×0,752203805029009404658202″2″5,0 – 8,042 – 2524 – 326-3
SHT6C-100/63×0,7522038050290011904658202″2″7,5 – 1242 – 2536 – 486-3
SHT6A-150/81×1,12203805029003402905701″2,5 – 4,250 – 3012 – 189 – 4
SHT6B-150/82×1,12203805029009404658202″2″5,0 – 8,450 – 3024 – 369 – 4
SHT6C-150/83×1,122038050290011904658202″2″7,5 – 12,650 – 3036-549 – 4
SHT6A-180/101×1,353805029003402906101″2,6 – 3,460 – 5012 – 1812 – 8
SHT6B-180/102×1,353805029009404658202″2″5,2 – 6,860 – 5024 – 3612 – 8
SHT6C-180/103×1,3538050290011904658202″2″7,6 – 10,260 – 5036 – 5412 – 8

Definition

Booster is systems that allow water to reach comfortably and the way of operation is completely automatic according to the intended use in cases where the city mains is insufficient, in high rise buildings, in residential units with tanks for water interruption.
These pumps are manufactured at frequencies of 50 Hz and 60 Hz.

Usage Areas

These booster sets are used in residential areas, industrial facilities, apartments, villas, schools, hospitals, factories and public housing, hotels, irrigation systems, treatment plants, heating and cooling systems.

SHT8 A

SHT8 B

SHT8 C

Techical Specifications

MOTORPUMP
TypeKWV
Mono
V
Tri
HzrpmW
mm
L
mm
H
mm

MANIFOLD INPUT

MANIFOLD OUTPUTMAX FLOW
m³/h
CAPACITY
mss
NUMBER OF FLATSNUMBER OF FLOORS
SHT8A-220/61×1,62203805029003502906103,5 – 670 – 4016 – 2814 – 6
SHT8B-220/62×1,62203805029009404658202″2″7 – 1270 – 4032 – 5614 – 6
SHT8C-220/63×1,622038050290011904658202″2″10,5 – 1870 – 4048 – 8414 – 6
SHT8A-300/81×2,23805029003502906104  – 5,580 – 6020-2817 – 10
SHT8B-300/82×2,23805029009404658202″2″8 – 1180 – 6040-5617 – 10
SHT8C-300/83×2,238050290011904658202″2″12 – 1680 – 6060-8417 – 10
SHT8A-400/101×33805029003502906404 – 590 – 8020– 2820 – 12
SHT8B-400/102×33805029009404658202″2″8 – 1090 – 8040 -5620 – 12
SHT8C-400/103×338050290011904658202″2″12 – 1590 – 8060 – 8420 – 12

Definition

Booster is systems that allow water to reach comfortably and the way of operation is completely automatic according to the intended use in cases where the city mains is insufficient, in high rise buildings, in residential units with tanks for water interruption.
These pumps are manufactured at frequencies of 50 Hz and 60 Hz.

Usage Areas

These booster sets are used in residential areas, industrial facilities, apartments, villas, schools, hospitals, factories and public housing, hotels, irrigation systems, treatment plants, heating and cooling systems.

SHT12 A

SHT12 B

SHT12 C

Techical Specifications

MOTORPUMP
TYPEKWV
Mono
V
Tri
HzrpmW
mm
L
mm
H
mm
MANIFOLD INPUTMANIFOLD OUTPUTMAX FLOW
m³/h
CAPACITY
mss
NUMBER OF FLATSNUMBER OF FLOORS
SHT12A-220/41×1,62203805029003502905805 – 950 – 3024 – 489 – 4
SHT12B-220/42×1,62203805029009404658202″2″10 – 1850 – 3048– 969 – 4
SHT12C-220/43×1,622038050290011904658202″2″15 – 2750 – 3072 – 1449 – 4
SHT12A-300/61×2,23805029003502905804 – 7,570 – 5024-3814 – 9
SHT12B-300/62×2,23805029009404658202″2″8 – 1570 – 5048-7614 – 9
SHT12C-300/63×2,238050290011904658202″2″12 – 22,570 – 5072-11414 – 9
SHT12A-400/71×33805029003502905853,5 – 780 – 7026-3417 – 14
SHT12B-400/72×33805029009404655852″2″7 – 1480 – 7052-6817 – 14
SHT12C-400/73×338050290011904655852″2″10 – 2180 – 7078-10217 – 14

Definition

Booster is systems that allow water to reach comfortably and the way of operation is completely automatic according to the intended use in cases where the city mains is insufficient, in high rise buildings, in residential units with tanks for water interruption.
These pumps are manufactured at frequencies of 50 Hz and 60 Hz.

Usage Areas

These booster sets are used in residential areas, industrial facilities, apartments, villas, schools, hospitals, factories and public housing, hotels, irrigation systems, treatment plants, heating and cooling systems.

SHT16 A

SHT16 B

SHT16 C

Techical Specifications

MOTOR

PUMP

TYPEKWVHzrpmW
mm
L
mm
H
mm
MANIFOLD INPUTMANIFOLD OUTPUTMAX FLOW
m³/h
CAPACITY
mss
NUMBER OF FLATSNUMBER OF FLOORS
SHT16A-550/41×43805029003703306204 – 1670 – 4020-4813-9
SHT16B-550/42×43805029009405508203″8 – 3270 – 4040-9613-9
SHT16C-550/43×438050290011905508203″12 – 4870 – 4060-14413-9
SHT16A-550/51×43805029003703306608 – 1190 – 6040-5414 – 11
SHT16B-550/52×43805029009405508203″16 – 2290 – 6080-10814 – 11
SHT16C-550/53×438050290011905508203″24 – 3390 – 60120-16214 – 11
SHT16A-750/61×5,53805029003703307007 – 14100 – 8034 – 6420-10
SHT16B-750/62×5,53805029009405508203″14 – 28100 – 8068 – 12820-10
SHT16C-750/63×5,538050290011905508203″21 – 42100 – 80102-19220-10
SHT16A-750/71×5,53805029003703307406 – 13110 – 9032– 6025 – 15
SHT16B-750/72×5,53805029009405508203″12 – 26110 – 9064 – 12025 – 15
SHT16C-750/73×5,538050290011905508203″18 – 39110 – 9096 – 18025 – 15
SHT16A-850/81×6,33805029003703307406 – 13120 – 10032 – 6028 – 18
SHT16B-850/82×6,33805029009405508203″12 – 26120 – 10064– 12028 – 18
SHT16C-850/83×6,338050290011905508203″18 – 39120 – 10096– 18428 – 18

Definition

Booster is systems that allow water to reach comfortably and the way of operation is completely automatic according to the intended use in cases where the city mains is insufficient, in high rise buildings, in residential units with tanks for water interruption.
These pumps are manufactured at frequencies of 50 Hz and 60 Hz.

Usage Areas

These booster sets are used in residential areas, industrial facilities, apartments, villas, schools, hospitals, factories and public housing, hotels, irrigation systems, treatment plants, heating and cooling systems.

SHT24 A

SHT24 B

SHT24 C

Techical Specifications

MOTORPUMP
TYPEKWVHzrpmW
mm
L
mm
H
mm
MANIFOLD INPUTMANIFOLD OUTPUTMAX FLOW
m³/h
CAPACITY
mss
NUMBER OF FLATSNUMBER OF FLOORS
SHT24A-750/41×5,538050290075051710652″9 – 2050 – 3042 – 958 – 3
SHT24B-750/42×5,5380502900110556710653″18 – 4050 – 3084 – 1908 – 3
SHT24C-750/43×5,538050290014507171065DN 1003″27 – 6050 – 30126 – 2858 – 3
SHT24A-750/51×5,538050290075051711152″10 – 1960 – 4048 – 8911 – 6
SHT24B-750/52×5,5380502900110556711153″20 – 3860 – 4096 – 17811 – 6
SHT24C-750/53×5,538050290014507171115DN 1003″30 – 5760 – 40144 – 26711 – 6
SHT24A-750/61×5,538050290075051711652″11 – 1870 – 5052 – 8514 – 8
SHT24B-750/62×5,5380502900110556711653″22 – 3670 – 50104 – 17014 – 8
SHT24C-750/63×5,538050290014507171165DN 1003″33 – 5470 – 50156 – 25514 – 8
SHT24A-1000/71×7,538050290075051712152″7 – 1790 – 6533 – 8020 – 12
SHT24B-1000/72×7,5380502900110556712153″14 – 3790 – 6566 – 16020 – 12
SHT24C-1000/73×7,538050290014507171215DN 1003″21 – 5190 – 6599 – 24020 – 12
SHT24A-1000/81×7,538050290075051712652″9 – 16100 – 8042 – 7623 – 17
SHT24B-1000/82×7,5380502900110556712653″18 – 32100 – 8084 – 15223 – 17
SHT24C-1000/83×7,538050290014507171265DN 1003″27 – 47100 – 80126 – 22823 – 17

Definition

Booster is systems that allow water to reach comfortably and the way of operation is completely automatic according to the intended use in cases where the city mains is insufficient, in high rise buildings, in residential units with tanks for water interruption.
These pumps are manufactured at frequencies of 50 Hz and 60 Hz.

Usage Areas

These booster sets are used in residential areas, industrial facilities, apartments, villas, schools, hospitals, factories and public housing, hotels, irrigation systems, treatment plants, heating and cooling systems.

SHT34 A

SHT34 B

SHT34 C

Techical Specifications

MOTORPUMP
TYPEKWVHzrpmW
mm
L
mm
H
mm
MANIFOLD INPUTMANIFOLD OUTPUTMAX FLOW
m³/h
CAPACITY
mss
NUMBER OF FLATSNUMBER OF FLOORS
SHT34A-750/41×5,538050290075051710652″16 – 2960 – 4076 – 13611 – 6
SHT34B-750/42×5,5380502900110556710653″32 – 5860 – 40152 – 27211 – 6
SHT34C-750/43×5,538050290014507171065DN 1003″48 – 8760 – 40228 – 40811 – 6
SHT34A-1000/51×7,538050290075051711152″12 – 2780 – 6056 – 12817 – 11
SHT34B-1000/52×7,5380502900110556711153″36 – 5480 – 60112 – 25617 – 11
SHT34C-1000/53×7,538050290014057171115DN 1003″36 – 8180 – 60168 – 38417 – 11
SHT34A-1500/61×1138050290075051711652″16 – 2890 – 7076 – 13020 – 14
SHT34B-1500/62×11380502900110556711653″32 – 5690 – 70152 – 26020 – 14
SHT34C-1500/63×1138050290014507171165DN 1003″48 – 8490 – 70228 – 39020 – 14
SHT34A-1500/71×1138050290075051712152″22 – 30100 – 80104 – 14023 – 17
SHT34B-1500/72×11380502900110556712153″44 – 60100 – 80210 – 28023 – 17
SHT34C-1500/73×1138050290014507171215DN 1003″66 – 90100 – 80312 – 42023 – 17

Definition

Booster is systems that allow water to reach comfortably and the way of operation is completely automatic according to the intended use in cases where the city mains is insufficient, in high rise buildings, in residential units with tanks for water interruption.
These pumps are manufactured at frequencies of 50 Hz and 60 Hz.

Usage Areas

These booster sets are used in residential areas, industrial facilities, apartments, villas, schools, hospitals, factories and public housing, hotels, irrigation systems, treatment plants, heating and cooling systems.

SHT44 A

SHT44 B

SHT44 C

Techical Specifications

MOTORPUMP
TypeKWVHzRpmW
mm
L
mm
H
mm
MANIFOLD INPUTMANIFOLD OUTPUTMAX FLOW
m³/h
CAPACITY
mss
NUMBER OF FLATSNUMBER OF FLOORS
SHT44A 1500/51×1138050290049068512003″36-255-7120-17014-8
SHT44B 1500/52×1138050290013358051225DN 1003″72-505-7240-34014-8
SHT44C 1500/53×1138050290017358301225DN 125DN 100108-755-7360-51014-8
SHT44A 1500/61×1138050290049068512503″33-237-9112-15520-14
SHT44B 1500/62×1138050290013358051270DN 1003″66-467-9220-31020-14
SHT44C 1500/63×1138050290017358301270DN 125DN 10098-697-9330-46520-14
SHT44A 2000/71×1538050290072068514003″33-268-10124-15423-17
SHT44B 2000/72×1538050290013358051425DN 1003″66-528-10248-31023-17
SHT44C 2000/73×1538050290017358301425DN 125DN 10099-788-10372-46523-17
SHT44A 2000/81×1538050290072068514503″32-2410-12114-15228-23
SHT44B 2000/82×1538050290013358051470DN 1003″64-4810-12228-30428-23
SHT44C 2000/83×1538050290017358301470DN 125DN 10096-7210-12342-45628-23

Definition

Booster is systems that allow water to reach comfortably and the way of operation is completely automatic according to the intended use in cases where the city mains is insufficient, in high rise buildings, in residential units with tanks for water interruption.
These pumps are manufactured at frequencies of 50 Hz and 60 Hz.

Usage Areas

These booster sets are used in residential areas, industrial facilities, apartments, villas, schools, hospitals, factories and public housing, hotels, irrigation systems, treatment plants, heating and cooling systems.

SHT60 A

SHT60 B

SHT60 C

Technical Specifications

MOTORPUMP
TypeKWVHzRpmW
mm
L
mm
H
mm
MANIFOLD INPUTMANIFOLD OUTPUTMAX FLOW
m³/h
CAPACITY
mss
NUMBER OF FLATSNUMBER OF FLOORS
SHT60A 2000/41×1538050290072068513303″56-385-7182-26014-8
SHT60B 2000/42×1538050290013358301350DN 125DN 100112-765-7364-52014-8
SHT60C 2000/43×1538050290017358601350DN 150DN 125168-1145-7546-78014-8
SHT60A 2000/51×1538050290072068513953″52-347-9165-24020-14
SHT60B 2000/52×1538050290013358301415DN 125DN 100104-687-9330-48020-14
SHT60C 2000/53×1538050290017358601415DN 150DN 125156-1027-9495-72020-14
SHT60A 2500/61×18.538050290072068514603″48-339-11155-23026-20
SHT60B 2500/62×18.538050290013358301480DN 125DN 10096-669-11310-46026-20
SHT60C 2500/63×18.538050290017358601480DN 150DN 125144-999-11465-69026-20

Definition

Booster is systems that allow water to reach comfortably and the way of operation is completely automatic according to the intended use in cases where the city mains is insufficient, in high rise buildings, in residential units with tanks for water interruption.
These pumps are manufactured at frequencies of 50 Hz and 60 Hz.

Usage Areas

These booster sets are used in residential areas, industrial facilities, apartments, villas, schools, hospitals, factories and public housing, hotels, irrigation systems, treatment plants, heating and cooling systems.

SHT32 A

SHT32 B

SHT32 C

Techical Specifications

MOTORPUMP
TYPEKWVHzrpmW
mm
L
mm
H
mm
MANIFOLD INPUTMANIFOLD OUTPUTMAX FLOW
m³/h
CAPACITY
mss
SHT 32/2 A1×3380502900335800111913 – 1940 – 20
SHT 32/2 B2×3380502900675141511193″26 – 3840 – 20
SHT 32/2 C3×33805029001106141511194″3″39 – 5740 – 20
SHT 32/3 A1×4380502900335800120910 – 1870 – 30
SHT 32/3 B2×4380502900675101512094″3″30 – 5470 – 30
SHT 32/3 C3×43805029001106101512094″3″30 – 5470 – 30
SHT 32/4 A1×5,5380502900335800127410 – 1990 – 60
SHT 32/4 B2×5,5380502900675101512743″20 – 3890 – 60
SHT 32/4 C3×5,53805029001106101512744″3″30 – 5790 – 60
SHT 32/5 A1×7,5380502900335800128512 – 17110 – 70
SHT 32/5 B2×7,5380502900675101513853″24 – 34110 – 70
SHT 32/5 C3×7,53805029001106101513854″3″36 – 51110 – 70
SHT 32/6 A1×11380502900335800147912 – 18130 – 90
SHT 32/6 B2×11380502900675101514793″24 – 36130 – 90
SHT 32/6 C3×113805029001106101414794″3″36 – 54130 – 90

Definition

Booster is systems that allow water to reach comfortably and the way of operation is completely automatic according to the intended use in cases where the city mains is insufficient, in high rise buildings, in residential units with tanks for water interruption.
These pumps are manufactured at frequencies of 50 Hz and 60 Hz.

Usage Areas

These booster sets are used in residential areas, industrial facilities, apartments, villas, schools, hospitals, factories and public housing, hotels, irrigation systems, treatment plants, heating and cooling systems.

SHT40 A

SHT40 B

SHT40 C

Techical Specifications

MOTORPUMP
TYPEKWVHzrpmW
mm
L
mm
H
mm
MANIFOLD INPUTMANIFOLD OUTPUTMAX FLOW
m³/h
CAPACITY
mss
SHT40/2 A1×7,538050290033580012552″32 – 3840 – 30
SHT40/2 B2×7,5380502900675141512553″3″64 – 7640 – 30
SHT40/2 C3×7,53805029001106141512555″4″96 – 11440 – 30
SHT40/3 A1×1138050290033580013562″20 – 3380 – 60
SHT40/3 B2×11380502900375101513563″3″40 – 6680 – 60
SHT40/3 C3×11380502900110610113565″4″60 – 9980 – 60
SHT40/4 A1×1538050290033580015112″20 – 34110 – 80
SHT40/4 B2×15380502900675101515113″3″40 – 68110 – 80
SHT40/4 C3×153805029001106101515115″4″60 – 102110 – 80
SHT40/5 A1×18,538050290033580016102″32 – 35130 – 90
SHT40/5 B2×18,5380502900675101516103″3″64 – 70130 – 90
SHT40/5 C3×18,53805029001106101516105″4″96 – 105130 – 90

Definition

Booster is systems that allow water to reach comfortably and the way of operation is completely automatic according to the intended use in cases where the city mains is insufficient, in high rise buildings, in residential units with tanks for water interruption.
These pumps are manufactured at frequencies of 50 Hz and 60 Hz.

Usage Areas

These booster sets are used in residential areas, industrial facilities, apartments, villas, schools, hospitals, factories and public housing, hotels, irrigation systems, treatment plants, heating and cooling systems.

SHT50 A

SHT50 B

SHT50 C

Techical Specifications

MOTORPUMP
TYPEKWVHzrpmW
mm
L
mm
H
mm
MANIFOLD INPUTMANIFOLD OUTPUTMAX FLOW
m³/h
CAPACITY
mss
SHT50/2 A1×1138050290043580014402″27 – 4865 – 50
SHT50/2 B2×11380502900875151514405″4″54 – 9665 – 50
SHT50/2 C3×113805029001350151514406″5″81 – 14465 – 50
SHT50/2 A1×1538050290043580015002″28 – 5080 – 60
SHT50/2 B2×15380502900875151515005″4″56 – 10080 – 60
SHT50/2 C3×153805029001350151515006″5″84 – 15080 – 60
SHT50/3 A1×18,538050290043580015902″27 – 55100 – 70
SHT50/3 B2×18,5380502900875101515905″4″54 – 110100 – 70
SHT50/3 C3×18,53805029001350101515906″5″81 – 165100 – 70
SHT50/3 A1×2238050290043580016702″20 – 52120 – 90
SHT50/3 B2×22380502900875101516705″4″40 – 104120 – 90
SHT50/3 C3×223805029001350101516706″5″60 – 156120 – 90
SHT50/4 A1×2238050290043580017202″20 – 50130 – 100
SHT50/4 B2×22380502900875101517205″4″40 – 100130 – 100
SHT50/4 C3×223805029001350101517206″5″60 – 150130 – 100
SHT50/4 A1×3038050290043580017502″25 – 50160 – 100
SHT50/4 B2×30380502900875101517505″4″50 – 100160 – 100
SHT50/4 C3×30380502901350101517506″5″75 – 150160 – 100

Definition

Booster systems are designed to maximize energy savings and provide constant pressure water in case of variable flow rate needs in cases where the city mains is insufficient, in high rise buildings, in residential units with tanks for water interruption.
These pumps are manufactured at frequencies of 50 Hz and 60 Hz.

Usage Areas

These booster sets are used in residential areas, industrial facilities, apartments, villas, schools, hospitals, factories and public housing, hotels, irrigation systems, treatment plants, heating and cooling systems.

SHT65 A

SHT65 B

SHT65 C

Techical Specifications

MOTORPUMP
TYPEKWVHzrpmW
mm
L
mm
H
mm
MANIFOLD INPUTMANIFOLD OUTPUTMAX FLOW
m³/h
CAPACITY
mss
SHT65/2 A1×3038050290043580015393″45 – 7575 – 60
SHT65/2 B2×30380502900975157015396″5″90 – 15075 – 60
SHT65/2 C3×303805029001466157015398″6″135 – 22575 – 60
SHT65/2 A1×3738050290043580015593″30 – 100100 – 80
SHT65/2 B2×37380502900975157015596″5″60 – 200100 – 80
SHT65/2 C3×373805029001466157015598″6″90 – 300100 – 80
SHT65/3 A1×4538050290043580017023″50 – 80130 – 120
SHT65/3 B2×45380502900975101517026″5″100 – 160130 – 120
SHT65/3 C3×453805029001466101517028″6″150 – 240130 – 120
SHT65/3 A1×5538050290043580017023″50 – 90150 – 135
SHT65/3 B2×5538050290097510151706″5″100 – 180150 – 135
SHT65/3 C3×553805029001466101517028″6″150 – 270150 – 135

Vertical Multistage Booster Sets

Vertical Shaft Multistage Pumps produced by turkish vertical multistage booster manufacturers  are products that make it easier to use in places where there is a horizontal space problem, they are used for hydrophore purposes, The pumps are designed with more than one impeller and stage on a vertical shaft. Although the material of the pump booster’s manufactured by turkish booster producers  impeller is usually noryl, they can also be manufactured as stainless and cast. Such pumps can also be used as fire pumps in small businesses. The asynchronous motor driving the pump is designed to be on the top of the pump, the pump is usually connected to the system with an easy mounting apparatus called a glen (flange) and can be easily disassembled in case of maintenance.

Booster systems from turkish booster suppliers  are used in industries, hospitals, residential units, hotels, mass housing, gas stations, holiday villages, shopping malls, social facilities, fire systems for booster purposes and pressurized water needs.

Hydrophore  from turkish hydrophore suppliers are electrically powered water pumps produced for the purpose of increasing the water pressure.

Regarding the selection of booster set, it should be known that , With the help of the working principle of the booster, high pressure, they deliver the water they suck from a certain water reservoir to far points. Thanks to the expansion tanks connected to the boosters, they already hold pressurized water.

Pressurized Water Boosters manufactured by turkish booster producers are used in buildings, apartments, detached villas, estates and high-rise buildings to meet the need for mains water or pressurized water from tanks in cases where the mains water pressure is not sufficient. In short, we can say that it is a water pressurization system used wherever the water pressure is insufficient. These systems, most of which work with electricity, increase the pressure of the water flowing from our taps.

Regarding the selection of the boosters , it should be known that , The difference between the booster and the pump is a detail that is often wondered. Let’s briefly explain this as follows. The booster is a whole system consisting of both the pump and the control equipment that controls the pump’s input and output.

The Booster Pump has a system consisting of protection equipment in order to ensure its long-lasting operation, so that it does not focus on a single purpose, the system in general provides control and protection.

Vertical Multistage Booster produced by turkish booster manufacturers is the name given to the pumps that are automatically activated when the water supply is insufficient. It pressurizes the water in the water tank with the pump wheels and pumps it to the far point, in short, this is the working principle. The selection of the booster pump should be completely tailored to the needs; It should be able to give the pressure to the water to go to the desired place. The booster is not only a system consisting of a water tank and a pump, but also has auxiliary elements mounted. We can count these auxiliary elements as follows; Expansion Tank, Manometer, Check Valve, Ball Valve, Pressure Switch, Control Panel and Water Level Floater.

There are some points when calculating the Gradual Booster; the number of flats and the height of the building, the location of the warehouse, the horizontal and vertical pipes in the building installation, the friction coefficient of the water in the water installation, the water supply for how many flats, the distance between the flats to be installed and the flats to be fed, etc. These details are important for choosing the right booster and provide long-term usefulness.

Read more